An open question for the biomechanical research community is accurate estimation of the volume and mass of each body segment of the human body, especially when indirect measurements are based on biomechanical modeling. Traditional methods involve the adoption of anthropometric tables, which describe only the average human shape, or manual measurements, which are time-consuming and depend on the operator. We propose a novel method based on the acquisition of a 3D scan of a subject’s body, which is obtained using a consumer-end RGB-D camera. The body segments’ separation is obtained by combining the body skeleton estimation of BlazePose with a biomechanical-coherent skeletal model, which is defined according to the literature. The volume of each body segment is computed using a 3D Monte Carlo procedure. Results were compared with manual measurement by experts, anthropometric tables, and a model leveraging truncated cone approximations, showing good adherence to reference data with minimal differences (ranging from +0.5 to −1.0 dm3 for the upper limbs, −0.1 to −4.2 dm3 for the thighs, and −0.4 to −2.3 dm3 for the shanks). In addition, we propose a novel indicator based on the computation of equivalent diameters for each body segment, highlighting the importance of gender-specific biomechanical models to account for the chest and pelvis areas of female subjects.

Measurement of Human Body Segment Properties Using Low-Cost RGB-D Cameras

Nuzzi, Cristina
Methodology
;
Ghidelli, Marco
Investigation
;
Lancini, Matteo
Validation
2025-01-01

Abstract

An open question for the biomechanical research community is accurate estimation of the volume and mass of each body segment of the human body, especially when indirect measurements are based on biomechanical modeling. Traditional methods involve the adoption of anthropometric tables, which describe only the average human shape, or manual measurements, which are time-consuming and depend on the operator. We propose a novel method based on the acquisition of a 3D scan of a subject’s body, which is obtained using a consumer-end RGB-D camera. The body segments’ separation is obtained by combining the body skeleton estimation of BlazePose with a biomechanical-coherent skeletal model, which is defined according to the literature. The volume of each body segment is computed using a 3D Monte Carlo procedure. Results were compared with manual measurement by experts, anthropometric tables, and a model leveraging truncated cone approximations, showing good adherence to reference data with minimal differences (ranging from +0.5 to −1.0 dm3 for the upper limbs, −0.1 to −4.2 dm3 for the thighs, and −0.4 to −2.3 dm3 for the shanks). In addition, we propose a novel indicator based on the computation of equivalent diameters for each body segment, highlighting the importance of gender-specific biomechanical models to account for the chest and pelvis areas of female subjects.
2025
Ateneo di appartenenza
LS7_1 Medical engineering and technology
PE2_17 Metrology and measurement
PE8_14 Industrial bioengineering
Inglese
Internazionale
ELETTRONICO
25
5
21
body segment parameters, measurement science, anthropometry, biomechanics, body volume estimation, Kinect Azure
UE
   EUropean ROBotic framework for bipedal locomotion bENCHmarking
   EUROBENCH
   European Commission
   Horizon 2020 Framework Programme
   779963
no
Goal 3: Good health and well-being
6
info:eu-repo/semantics/article
262
Nuzzi, Cristina; Ghidelli, Marco; Luchetti, Alessandro; Zanetti, Matteo; Crenna, Francesco; Lancini, Matteo
1 Contributo su Rivista::1.1 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
2025_Measurement of Human Body Segment Properties Using Low-Cost RGB-D Cameras - convertito.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/623485
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact