Background: This study evaluates the repeatability and reproducibility of fat-fraction percentage (FF%) in whole-body magnetic resonance imaging (WB-MRI) of prostate cancer patients with bone metastatic hormone naive disease. Methods: Patients were selected from the database of a prospective phase-II trial. The treatment response was assessed using the METastasis Reporting and Data System for Prostate (MET-RADS-P). Two operators identified a Small Active Lesion (SAL, <10 mm) and a Large Active Lesion (LAL, >= 10 mm) per patient, performing manual segmentation of lesion volume and the largest cross-sectional area. Measurements were repeated by one operator after two weeks. Intra- and inter-reader agreements were assessed via Interclass Correlation Coefficient (ICC) on first-order radiomics features. Results: Intra-reader ICC showed high repeatability for both SAL and LAL in a single slice (SS) and volumetric (VS) measurements with values ranging from 0.897 to 0.971. Inter-reader ICC ranged from 0.641 to 0.883, indicating moderate to good reproducibility. Spearman's rho analysis confirmed a strong correlation between SS and VS measurements for SAL (0.817) and a moderate correlation for LAL (0.649). Both intra- and inter-rater agreement exceeded 0.75 for multiple first-order features across lesion sizes. Conclusion: This study suggests that FF% measurements are reproducible, particularly for larger lesions in both SS and VS assessments.

Fat Fraction Extracted from Whole-Body Magnetic Resonance (WB-MR) in Bone Metastatic Prostate Cancer: Intra- and Inter-Reader Agreement of Single-Slice and Volumetric Measurements

Di Meo, Nunzia;Rondi, Paolo;Saeli, Chiara;Dalla Volta, Alberto;Vezzoli, Marika;Berruti, Alfredo;Borghesi, Andrea;Maroldi, Roberto;Ravanelli, Marco;Farina, Davide
2024-01-01

Abstract

Background: This study evaluates the repeatability and reproducibility of fat-fraction percentage (FF%) in whole-body magnetic resonance imaging (WB-MRI) of prostate cancer patients with bone metastatic hormone naive disease. Methods: Patients were selected from the database of a prospective phase-II trial. The treatment response was assessed using the METastasis Reporting and Data System for Prostate (MET-RADS-P). Two operators identified a Small Active Lesion (SAL, <10 mm) and a Large Active Lesion (LAL, >= 10 mm) per patient, performing manual segmentation of lesion volume and the largest cross-sectional area. Measurements were repeated by one operator after two weeks. Intra- and inter-reader agreements were assessed via Interclass Correlation Coefficient (ICC) on first-order radiomics features. Results: Intra-reader ICC showed high repeatability for both SAL and LAL in a single slice (SS) and volumetric (VS) measurements with values ranging from 0.897 to 0.971. Inter-reader ICC ranged from 0.641 to 0.883, indicating moderate to good reproducibility. Spearman's rho analysis confirmed a strong correlation between SS and VS measurements for SAL (0.817) and a moderate correlation for LAL (0.649). Both intra- and inter-rater agreement exceeded 0.75 for multiple first-order features across lesion sizes. Conclusion: This study suggests that FF% measurements are reproducible, particularly for larger lesions in both SS and VS assessments.
File in questo prodotto:
File Dimensione Formato  
Fat Fraction Extracted from Whole-Body Magnetic Resonance.pdf

accesso aperto

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/611466
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact