Abstract: Background: The choice of the correct color is of paramount importance in esthetic dentistry; however, there is still no consensus on the best technique to determine it. The aim of the present study is to compare the accuracy of a recently introduced colorimeter in shade matching with human vision. In addition, possible variables affecting color-matching by human eye have been analysed. Methods: 18 disc-shaped composite samples with identical size and shape were produced from a composite flow system (Enamel plus HriHF, Micerium): Nine were considered control samples (UD 0-UD 6), and nine were test samples with identical flow composite shade to the control ones. Parallelly, 70 individuals (dental students and dental field professionals) were individually instructed to sit in a dark room illuminated with D55 light and to perform visual shade matching between control and test discs. An error matrix containing ∆E94 between control and test discs was generated, containing four match-clusters depending on perceptibility and acceptability thresholds. The frequency and severity of errors were examined. Results: The colorimeter achieved a 100% perfect matching, while individuals only achieved a 78%. A higher occurrence of mismatches was noted for intermediate composite shades without a statistically significant difference. No statistically significant differences were reported for age, sex, and experience. A statistically significant difference was present among the Optishade match and the visual determination. Conclusions: The instrumental shade-matching evaluation proved to be significantly more reliable than the human visual system. Further research is needed to determine whether the same outcomes are achieved in a clinical setting directly on patients.

Dental Color-Matching Ability: Comparison between Visual Determination and Technology

Kovacs-Vajna, Zsolt M.;
2024-01-01

Abstract

Abstract: Background: The choice of the correct color is of paramount importance in esthetic dentistry; however, there is still no consensus on the best technique to determine it. The aim of the present study is to compare the accuracy of a recently introduced colorimeter in shade matching with human vision. In addition, possible variables affecting color-matching by human eye have been analysed. Methods: 18 disc-shaped composite samples with identical size and shape were produced from a composite flow system (Enamel plus HriHF, Micerium): Nine were considered control samples (UD 0-UD 6), and nine were test samples with identical flow composite shade to the control ones. Parallelly, 70 individuals (dental students and dental field professionals) were individually instructed to sit in a dark room illuminated with D55 light and to perform visual shade matching between control and test discs. An error matrix containing ∆E94 between control and test discs was generated, containing four match-clusters depending on perceptibility and acceptability thresholds. The frequency and severity of errors were examined. Results: The colorimeter achieved a 100% perfect matching, while individuals only achieved a 78%. A higher occurrence of mismatches was noted for intermediate composite shades without a statistically significant difference. No statistically significant differences were reported for age, sex, and experience. A statistically significant difference was present among the Optishade match and the visual determination. Conclusions: The instrumental shade-matching evaluation proved to be significantly more reliable than the human visual system. Further research is needed to determine whether the same outcomes are achieved in a clinical setting directly on patients.
File in questo prodotto:
File Dimensione Formato  
dentistryJournal2024.pdf

accesso aperto

Tipologia: Full Text
Licenza: Creative commons
Dimensione 1.56 MB
Formato Adobe PDF
1.56 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/608325
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact