The evaluation of the morphological characteristics of small resistance arteries in human beings is not easy. The gold standard is generally considered to be the evaluation of the media to lumen ratio (MLR) of subcutaneous small vessels obtained by local biopsies and evaluated by wire or pressure micromyiography. However, non-invasive techniques for the evaluation of retinal arterioles were recently proposed, in particular two approaches seem to provide interesting information: scanning laser Doppler flowmetry (SLDF) and adaptive optics (AO); both of them provide an estimation of the wall to lumen ratio (WLR) of retinal arterioles, as well as of internal and external diameters and wall cross-sectional area.

POOR CONCORDANCE BETWEEN NON-INVASIVE AND LOCALLY INVASIVE TECHNIQUES OF EVALUATION OF MICROVASCULAR MORPHOLOGY IN THE DETECTION OF HYPERTROPHIC REMODELING OF SMALL RESISTANCE ARTERIES

C. De Ciuceis;S. Caletti;M. Coschignano;C. Rossini;S. Duse;F. Docchio;S. Pasinetti;F. Semeraro;V. Trapletti;M. Nardin;C. Agabiti Rosei;D. Rizzoni
2018-01-01

Abstract

The evaluation of the morphological characteristics of small resistance arteries in human beings is not easy. The gold standard is generally considered to be the evaluation of the media to lumen ratio (MLR) of subcutaneous small vessels obtained by local biopsies and evaluated by wire or pressure micromyiography. However, non-invasive techniques for the evaluation of retinal arterioles were recently proposed, in particular two approaches seem to provide interesting information: scanning laser Doppler flowmetry (SLDF) and adaptive optics (AO); both of them provide an estimation of the wall to lumen ratio (WLR) of retinal arterioles, as well as of internal and external diameters and wall cross-sectional area.
2018
2018
Ateneo di appartenenza
LS4_7 Cardiovascular diseases
LS5_4 Sensory systems (e.g. visual system, auditory system)
LS7_2 Diagnostic tools (e.g. genetic, imaging)
Esperti anonimi
Inglese
Internazionale
STAMPA
36
e197
e198
2
28th European Meeting on Hypertension and Cardiovascular Protection, Barcelona, June 8-11, 2018
Small resistance, techniques of evaluation of microvascular morphology, wall-to-lumen ratio of retinal arterioles
Altra università italiana
no
info:eu-repo/semantics/article
266
reserved
12
1 Contributo su Rivista::1.5 Abstract in rivista
De Ciuceis, C.; Caletti, S.; Coschignano, M.; Rossini, C.; Duse, S.; Docchio, F.; Pasinetti, S.; Semeraro, F.; Trapletti, V.; Nardin, M.; Agabiti Rose...espandi
File in questo prodotto:
File Dimensione Formato  
POOR CONCORDANCE BETWEEN NON-INVASIVE AND LOCALLY INVASIVE T... _ Journal of.pdf

gestori archivio

Descrizione: Abstract ESH 2018
Tipologia: Abstract
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 316.57 kB
Formato Adobe PDF
316.57 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/509908
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact