Four commercial hydroxyapatites (both natural and synthetic) were tested to assess transformations of the chemical and crystalline structure following variation of temperature from 20 to 1600 degrees C. The thermal behaviour of hydroxyapatite is relevant for biomedical applications such as plasma spraying of metallic implants. Thermogravimetric analysis showed a weight loss from each hydroxyapatite specimen, due to a release of structural H2O molecules; all the specimens up to 1300 degrees C were made of crystalline hydroxyapatite, determined by X-ray diffraction; at 1470 degrees C they were made of both hydroxyapatite and calcium phosphate, but at 1570 degrees C of calcium phosphate exclusively. The diffractograms of the hydroxyapatite coatings showed the same peaks as the original powders, so at the chosen plasma-spray procedure level no new phases were formed. The peak height was nevertheless lower in the plasma-sprayed hydroxyapatites for all interplanar spacing values, which indicated a lower degree of crystallinity, associated with a random structure derived from an alteration to the original crystalline network.

Thermal behaviour of hydroxyapatite intended for medical applications.

PAZZAGLIA, Ugo;
1993-01-01

Abstract

Four commercial hydroxyapatites (both natural and synthetic) were tested to assess transformations of the chemical and crystalline structure following variation of temperature from 20 to 1600 degrees C. The thermal behaviour of hydroxyapatite is relevant for biomedical applications such as plasma spraying of metallic implants. Thermogravimetric analysis showed a weight loss from each hydroxyapatite specimen, due to a release of structural H2O molecules; all the specimens up to 1300 degrees C were made of crystalline hydroxyapatite, determined by X-ray diffraction; at 1470 degrees C they were made of both hydroxyapatite and calcium phosphate, but at 1570 degrees C of calcium phosphate exclusively. The diffractograms of the hydroxyapatite coatings showed the same peaks as the original powders, so at the chosen plasma-spray procedure level no new phases were formed. The peak height was nevertheless lower in the plasma-sprayed hydroxyapatites for all interplanar spacing values, which indicated a lower degree of crystallinity, associated with a random structure derived from an alteration to the original crystalline network.
1993
Altra università italiana
LS3_1 Morphology and functional imaging of cells
Inglese
14
437
441
4
info:eu-repo/semantics/article
262
Locardi, B; Pazzaglia, Ugo; Gabbi, C; Profilo, B.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/8216
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact