The use of non-conventional systems for domestic wastewater management has gained attention in rural areas of the Global South, where centralised infrastructure is often limited. This study presents the design, construction, and pilot-scale evaluation of a solar still unit operated under passive and photovoltaic-assisted active modes as a separation and polishing component for domestic wastewater from a rural site in Barrancabermeja, Colombia. Performance was assessed through physicochemical and microbiological characterisation of influent wastewater and treated condensate, together with hourly monitoring of distillate production, water temperature, glass-cover temperature, and ambient conditions. Under passive operation, a theoretical distillation model was applied, empirically adjusted, and evaluated using MAE, RMSE, MAPE, and R2. Under the tested conditions, indicative within-mode reductions reached 80.9% and 89.3% for chemical oxygen demand (COD), 95.6% and 93.8% for biochemical oxygen demand (BOD5), and 94.0% and 94.4% for total suspended solids (TSS) under passive and active modes, respectively. Microbial indicators showed minimum estimated reductions above 99.9%, with faecal coliforms reduced to very low levels in passive mode and not detected in the analysed active-mode condensate sample. Maximum daily condensate production reached 1.445 L m−2 day−1 in passive mode and 2.262 L m−2 day−1 in active mode, confirming the low-flow nature of the unit. Approximately 50% of daily production occurred between 12:00 and 15:00 h. The model reproduced the main diurnal production pattern, although empirical correction was required. Overall, the unit may improve condensate quality under pilot-scale conditions and shows potential as a polishing component within decentralised, low-flow treatment trains.

Solar Still Unit as a Component of Domestic Wastewater Treatment in Isolated Rural Communities: A Case Study in Colombia

Alessandro Abba';Marta Domini;Sabrina Sorlini;Mentore Vaccari
2026-01-01

Abstract

The use of non-conventional systems for domestic wastewater management has gained attention in rural areas of the Global South, where centralised infrastructure is often limited. This study presents the design, construction, and pilot-scale evaluation of a solar still unit operated under passive and photovoltaic-assisted active modes as a separation and polishing component for domestic wastewater from a rural site in Barrancabermeja, Colombia. Performance was assessed through physicochemical and microbiological characterisation of influent wastewater and treated condensate, together with hourly monitoring of distillate production, water temperature, glass-cover temperature, and ambient conditions. Under passive operation, a theoretical distillation model was applied, empirically adjusted, and evaluated using MAE, RMSE, MAPE, and R2. Under the tested conditions, indicative within-mode reductions reached 80.9% and 89.3% for chemical oxygen demand (COD), 95.6% and 93.8% for biochemical oxygen demand (BOD5), and 94.0% and 94.4% for total suspended solids (TSS) under passive and active modes, respectively. Microbial indicators showed minimum estimated reductions above 99.9%, with faecal coliforms reduced to very low levels in passive mode and not detected in the analysed active-mode condensate sample. Maximum daily condensate production reached 1.445 L m−2 day−1 in passive mode and 2.262 L m−2 day−1 in active mode, confirming the low-flow nature of the unit. Approximately 50% of daily production occurred between 12:00 and 15:00 h. The model reproduced the main diurnal production pattern, although empirical correction was required. Overall, the unit may improve condensate quality under pilot-scale conditions and shows potential as a polishing component within decentralised, low-flow treatment trains.
File in questo prodotto:
File Dimensione Formato  
ChemEngineering-10-00086.pdf

accesso aperto

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 16.65 MB
Formato Adobe PDF
16.65 MB Adobe PDF Visualizza/Apri
ChemEngineering-10-00086.zip

accesso aperto

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 15.25 MB
Formato Zip File
15.25 MB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/651185
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact