INTRODUCTION: For routine clinical implementation of Alzheimer's disease (AD) plasma biomarkers, fully automated random-access platforms are crucial to ensure reproducible measurements. We aimed to perform an analytical validation and to establish cutoffs for AD plasma biomarkers measured with Lumipulse. METHODS: Two cohorts were included. UNIPG: n = 450 paired cerebrospinal fluid (CSF)/plasma samples from subjects along the AD-continuum, subjects affected by other neurodegenerative diseases, and controls with known CSF profile; AMS: n = 40 plasma samples from AD and n = 40 controls. Plasma amyloid β (Aβ)42, Aβ40, and p-tau181 were measured with Lumipulse. We evaluated analytical and diagnostic performance. RESULTS: Lumipulse assays showed high analytical performance. Plasma p-tau181 levels accurately reflected CSF A+/T+ profile in AD-dementia and mild cognitive impairment (MCI)-AD, but not in asymptomatic-AD. Plasma and CSF Aβ42/40 values were concordant across clinical AD stages. Cutoffs and probability-based models performed satisfactorily in both cohorts. DISCUSSION: The identified cutoffs and probability-based models represent a significant step toward plasma AD molecular diagnosis.

Fully automated measurement of plasma Aβ42/40 and p-tau181: Analytical robustness and concordance with cerebrospinal fluid profile along the Alzheimer's disease continuum in two independent cohorts

Toja A.;
2024-01-01

Abstract

INTRODUCTION: For routine clinical implementation of Alzheimer's disease (AD) plasma biomarkers, fully automated random-access platforms are crucial to ensure reproducible measurements. We aimed to perform an analytical validation and to establish cutoffs for AD plasma biomarkers measured with Lumipulse. METHODS: Two cohorts were included. UNIPG: n = 450 paired cerebrospinal fluid (CSF)/plasma samples from subjects along the AD-continuum, subjects affected by other neurodegenerative diseases, and controls with known CSF profile; AMS: n = 40 plasma samples from AD and n = 40 controls. Plasma amyloid β (Aβ)42, Aβ40, and p-tau181 were measured with Lumipulse. We evaluated analytical and diagnostic performance. RESULTS: Lumipulse assays showed high analytical performance. Plasma p-tau181 levels accurately reflected CSF A+/T+ profile in AD-dementia and mild cognitive impairment (MCI)-AD, but not in asymptomatic-AD. Plasma and CSF Aβ42/40 values were concordant across clinical AD stages. Cutoffs and probability-based models performed satisfactorily in both cohorts. DISCUSSION: The identified cutoffs and probability-based models represent a significant step toward plasma AD molecular diagnosis.
2024
Inglese
20
4
2453
2468
16
Alzheimer's disease; automated platforms; Aβ; p-tau; plasma biomarkers
Goal 3: Good health and well-being
14
info:eu-repo/semantics/article
262
Bellomo, G.; Bayoumy, S.; Megaro, A.; Toja, A.; Nardi, G.; Gaetani, L.; Blujdea, E. R.; Paolini Paoletti, F.; Wojdala, A. L.; Chiasserini, D.; Van Der...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
Alzheimer s Dementia - 2024 - Bellomo - Fully automated measurement of plasma A 42 40 and p‐tau181 Analytical robustness.pdf

accesso aperto

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 3.01 MB
Formato Adobe PDF
3.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/647593
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 35
  • ???jsp.display-item.citation.isi??? ND
social impact