Accurate assessment of biomechanical risk associated with pushing/pulling tasks represents a challenging issue, especially in the health system where personnel are often required to maneuver beds and carts. Most studies in this field have been carried out in laboratory, while few data have been collected under actual working conditions. This study aims to characterize the forces exerted during non-powered hospital bed maneuvering. Twenty participants were required to move a bed (equipped with a customized handlebar to measure exerted forces) along an actual hospital path which included straight, turn and maneuver phases. The results show that the higher forces are associated with the initial phase (peak and mean values 222 and 68 N) while straight, turn and maneuvering phases required similar (lower) efforts. The combined effect of left, right and transversal forces suggests that the trunk of the operator might experience axial rotation, thus calling for further investigations on this aspect.

Characterization of hand forces exerted during non-powered hospital bed pushing and pulling tasks

Lecca, L I;Monticone, M;Campagna, M
2022-01-01

Abstract

Accurate assessment of biomechanical risk associated with pushing/pulling tasks represents a challenging issue, especially in the health system where personnel are often required to maneuver beds and carts. Most studies in this field have been carried out in laboratory, while few data have been collected under actual working conditions. This study aims to characterize the forces exerted during non-powered hospital bed maneuvering. Twenty participants were required to move a bed (equipped with a customized handlebar to measure exerted forces) along an actual hospital path which included straight, turn and maneuver phases. The results show that the higher forces are associated with the initial phase (peak and mean values 222 and 68 N) while straight, turn and maneuvering phases required similar (lower) efforts. The combined effect of left, right and transversal forces suggests that the trunk of the operator might experience axial rotation, thus calling for further investigations on this aspect.
File in questo prodotto:
File Dimensione Formato  
JOSE_2021.pdf

gestori archivio

Licenza: DRM non definito
Dimensione 927.74 kB
Formato Adobe PDF
927.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/642674
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
social impact