Introduction: Further research is needed to understand the performance of plasma phosphorylated tau (p-tau)217 in the diagnostic thinking at the individual patient level. We evaluated the incremental diagnostic value of plasma p-tau217, expressed in terms of diagnostic confidence of Alzheimer's disease (DCAD; range 0-100). Methods: Two hundred thirty-two patients with dementia were included and scored in terms of DCAD in a three-step consecutive assessment: (1) clinical work-up, (2) clinical work-up plus plasma p-tau217, and (3) clinical work-up, plasma p-tau217, plus conventional amyloid markers. Two blinded neurologists were asked to review DCAD at each step. Results: DCAD accuracy, expressed as area under the curve, significantly increased from 0.93 with clinical work-up alone, to 0.97 with clinical work-up plus plasma p-tau217 (P = 0.01), with no further increase with the addition of conventional amyloid markers (0.99, P = 0.13). Discussion: Plasma p-tau217 in addition to routine assessment significantly enhances diagnostic confidence that is comparable to well-established amyloidosis biomarkers. Highlights: Plasma phosphorylated tau (p-tau)217 measurements increase diagnostic confidence of Alzheimer's disease. Plasma p-tau217 increases diagnostic confidence comparable to traditional markers. Plasma p-tau217 dosage may be helpful in addition to routine assessment.

Disclosure of plasma p-tau217 measure improves diagnostic confidence in patients with Alzheimer's disease versus syndromes associated with frontotemporal lobar degeneration

Cantoni V.;Cotelli M. S.;Rota M.;Alberici A.;Libri I.;Ghidoni R.;Bellini S.;Borroni B.
2025-01-01

Abstract

Introduction: Further research is needed to understand the performance of plasma phosphorylated tau (p-tau)217 in the diagnostic thinking at the individual patient level. We evaluated the incremental diagnostic value of plasma p-tau217, expressed in terms of diagnostic confidence of Alzheimer's disease (DCAD; range 0-100). Methods: Two hundred thirty-two patients with dementia were included and scored in terms of DCAD in a three-step consecutive assessment: (1) clinical work-up, (2) clinical work-up plus plasma p-tau217, and (3) clinical work-up, plasma p-tau217, plus conventional amyloid markers. Two blinded neurologists were asked to review DCAD at each step. Results: DCAD accuracy, expressed as area under the curve, significantly increased from 0.93 with clinical work-up alone, to 0.97 with clinical work-up plus plasma p-tau217 (P = 0.01), with no further increase with the addition of conventional amyloid markers (0.99, P = 0.13). Discussion: Plasma p-tau217 in addition to routine assessment significantly enhances diagnostic confidence that is comparable to well-established amyloidosis biomarkers. Highlights: Plasma phosphorylated tau (p-tau)217 measurements increase diagnostic confidence of Alzheimer's disease. Plasma p-tau217 increases diagnostic confidence comparable to traditional markers. Plasma p-tau217 dosage may be helpful in addition to routine assessment.
File in questo prodotto:
File Dimensione Formato  
Alzheimer s Dementia - 2025 - Cantoni - Disclosure of plasma p‐tau217 measure improves diagnostic confidence in patients.pdf

accesso aperto

Descrizione: full-text Alzheimers Dement . 2025 May;21(5):e70289
Tipologia: Full Text
Licenza: PUBBLICO - Creative Commons 4.0
Dimensione 332.59 kB
Formato Adobe PDF
332.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/627165
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact