This clinical study evaluated the survival of monolithic lithium disilicate (ML) (IPS Emax, Ivoclar Vivadent) restorations bonded to complete-arch CAD/CAM made titanium or zirconia frameworks. Between August 2007 and December 2009, 15 patients (7 fe-male, 8 male; mean age: 56.8 years old) received 30 implant-supported screw-retained rehabilitations with ML restorations cemented to CAD/CAM made titanium (T) (n=6) or zirconia (Z) frameworks (n=24) adhesively (Multilink Automix, RelyX Unicem) and followed up until December 2015. The evaluation protocol involved technical failures (chip-ping, debonding or fracture of crown/framework, screw loosening), Californian Dental Association (CDA) quality criteria (Romeo: Excellent; Sierra: Acceptable; Tango: Retriev-able; Victor: Not acceptable) and biological failures (mucositis, peri-implantitis). Mean observation time was 60.3 months. No implants were lost, and all the prostheses were in situ. Four mechanical failures occurred in the form of minor chipping (n=3 in ML-Z, n=1 in ML-T) and major fracture in ML crown (n=1 in ML-Z). Romeo scores (N=370) decreased until final observation (N=347) and 23 Sierra scores were given to the restorations. Mu-cositis was observed in 3 patients and peri-implantitis in one patient. Complete-arch implant-borne FDPs made of monolithic lithium disilicate bonded to titanium or zirconia frameworks could be a promising alternative.

Clinical Performance of Complete-Arch Implant- Supported Rehabilitations Using Monolithic Lithium Disilicate Restorations Bonded to CAD/CAM Titanium and Zirconia Frameworks up to 5 Years

Cerutti, A;
2022-01-01

Abstract

This clinical study evaluated the survival of monolithic lithium disilicate (ML) (IPS Emax, Ivoclar Vivadent) restorations bonded to complete-arch CAD/CAM made titanium or zirconia frameworks. Between August 2007 and December 2009, 15 patients (7 fe-male, 8 male; mean age: 56.8 years old) received 30 implant-supported screw-retained rehabilitations with ML restorations cemented to CAD/CAM made titanium (T) (n=6) or zirconia (Z) frameworks (n=24) adhesively (Multilink Automix, RelyX Unicem) and followed up until December 2015. The evaluation protocol involved technical failures (chip-ping, debonding or fracture of crown/framework, screw loosening), Californian Dental Association (CDA) quality criteria (Romeo: Excellent; Sierra: Acceptable; Tango: Retriev-able; Victor: Not acceptable) and biological failures (mucositis, peri-implantitis). Mean observation time was 60.3 months. No implants were lost, and all the prostheses were in situ. Four mechanical failures occurred in the form of minor chipping (n=3 in ML-Z, n=1 in ML-T) and major fracture in ML crown (n=1 in ML-Z). Romeo scores (N=370) decreased until final observation (N=347) and 23 Sierra scores were given to the restorations. Mu-cositis was observed in 3 patients and peri-implantitis in one patient. Complete-arch implant-borne FDPs made of monolithic lithium disilicate bonded to titanium or zirconia frameworks could be a promising alternative.
File in questo prodotto:
File Dimensione Formato  
Clinical_Performance_of_Complete_Arch_Im.pdf

gestori archivio

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 767.74 kB
Formato Adobe PDF
767.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/622525
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact