Cellular barriers control fundamental physiological functions in animals and plants. Accurate detection of barrier dysfunction requires real-time monitoring. Organic electrochemical transistors are a promising bioelectronic platform to monitoring cellular barriers. However, current approaches are not ideally suited for direct and real-time measurements: they require off-line model-based data analysis or slow measurement operation to achieve equilibrium conditions. Herein, dynamic-mode current-driven organic electrochemical transistors are proposed for direct real-time monitoring of cellular barrier functionality. In contrast to current approaches, the organic electrochemical transistor is operated under nonequilibrium conditions. The approach shows a sensitivity larger than 350 × 10−6 V (Ω cm2)−1 with an operating range of 13–640 Ω cm2. The sensitivity can be optimized on-line by simply changing the dynamic conditions and real-time monitoring of reversible barrier functionality is demonstrated by using a tight-junction modulator with a concentration as-low-as 122 × 10−6 m. The theoretical foundation of the method is provided. The analysis shows the general applicability of the approach, opening opportunities for precision in vitro bioelectronics and medical diagnostic.

Real‐Time Monitoring of Cellular Barrier Functionality with Dynamic‐Mode Current‐Driven Organic Electrochemical Transistor

Torricelli, Fabrizio
2023-01-01

Abstract

Cellular barriers control fundamental physiological functions in animals and plants. Accurate detection of barrier dysfunction requires real-time monitoring. Organic electrochemical transistors are a promising bioelectronic platform to monitoring cellular barriers. However, current approaches are not ideally suited for direct and real-time measurements: they require off-line model-based data analysis or slow measurement operation to achieve equilibrium conditions. Herein, dynamic-mode current-driven organic electrochemical transistors are proposed for direct real-time monitoring of cellular barrier functionality. In contrast to current approaches, the organic electrochemical transistor is operated under nonequilibrium conditions. The approach shows a sensitivity larger than 350 × 10−6 V (Ω cm2)−1 with an operating range of 13–640 Ω cm2. The sensitivity can be optimized on-line by simply changing the dynamic conditions and real-time monitoring of reversible barrier functionality is demonstrated by using a tight-junction modulator with a concentration as-low-as 122 × 10−6 m. The theoretical foundation of the method is provided. The analysis shows the general applicability of the approach, opening opportunities for precision in vitro bioelectronics and medical diagnostic.
File in questo prodotto:
File Dimensione Formato  
AMT,2201697(2023).pdf

accesso aperto

Tipologia: Full Text
Licenza: Creative commons
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/616785
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact