Purpose:The objective of this study is to validate Descemet membrane endothelial keratoplasty (DMEK) Rapid device for preloading DMEK grafts with endothelium outward.Methods:In this multicenter retrospective clinical study, DMEK tissues (n = 27) were peeled and preloaded (8.25 mm) in a DMEK Rapid device. The device was loaded in a container prefilled with the storage solution and shipped from a single center in Italy to 4 different centers located in Italy and the United Kingdom. Preloaded tissues were delivered by injecting the graft in the anterior chamber. Patients were monitored at days 1 and 15 and at months 1, 3, and 6, as well as at the last follow-up (9-12 months) postoperatively. Main outcome measures included rebubbling rate and graft failure, corrected distance visual acuity, endothelial cell loss (ECL), and central corneal thickness at all time points. A one-way analysis of variance test comparing day 1 with all later time points was followed with significance at P & lt; 0.05.Results:The average recorded surgical time was 6 to 25 minutes with no immediate surgical complications. Rebubbling was observed in 7 of 26 cases with one graft failure within 15 days postoperatively. The mean corrected distance visual acuity at day 1 was 0.64 & plusmn; 0.49 logMAR, which improved to 0.18 & plusmn; 0.43 logMAR at the last follow-up. Endothelial cell density values showed a significant decrease at the last follow-up (1827 & plusmn; 565 cells/mm2) (P & lt; 0.001) compared with the preoperative value (2503 & plusmn; 128 cells/mm2), with an average endothelial cell loss of 27%. Central corneal thickness significantly dropped from 694 & plusmn; 157 m at day 1 to 502 & plusmn; 42 m at the last follow-up (P & lt; 0.001).Conclusions:DMEK Rapid device is quick, easy, and efficient for preloading and shipping DMEK grafts internationally in endothelium-outward orientation.

Preloaded DMEK with Endothelium Outward: A Multicenter Clinical Study Using DMEK Rapid Device

Romano V.;
2024-01-01

Abstract

Purpose:The objective of this study is to validate Descemet membrane endothelial keratoplasty (DMEK) Rapid device for preloading DMEK grafts with endothelium outward.Methods:In this multicenter retrospective clinical study, DMEK tissues (n = 27) were peeled and preloaded (8.25 mm) in a DMEK Rapid device. The device was loaded in a container prefilled with the storage solution and shipped from a single center in Italy to 4 different centers located in Italy and the United Kingdom. Preloaded tissues were delivered by injecting the graft in the anterior chamber. Patients were monitored at days 1 and 15 and at months 1, 3, and 6, as well as at the last follow-up (9-12 months) postoperatively. Main outcome measures included rebubbling rate and graft failure, corrected distance visual acuity, endothelial cell loss (ECL), and central corneal thickness at all time points. A one-way analysis of variance test comparing day 1 with all later time points was followed with significance at P & lt; 0.05.Results:The average recorded surgical time was 6 to 25 minutes with no immediate surgical complications. Rebubbling was observed in 7 of 26 cases with one graft failure within 15 days postoperatively. The mean corrected distance visual acuity at day 1 was 0.64 & plusmn; 0.49 logMAR, which improved to 0.18 & plusmn; 0.43 logMAR at the last follow-up. Endothelial cell density values showed a significant decrease at the last follow-up (1827 & plusmn; 565 cells/mm2) (P & lt; 0.001) compared with the preoperative value (2503 & plusmn; 128 cells/mm2), with an average endothelial cell loss of 27%. Central corneal thickness significantly dropped from 694 & plusmn; 157 m at day 1 to 502 & plusmn; 42 m at the last follow-up (P & lt; 0.001).Conclusions:DMEK Rapid device is quick, easy, and efficient for preloading and shipping DMEK grafts internationally in endothelium-outward orientation.
File in questo prodotto:
File Dimensione Formato  
preloaded_dmek_with_endothelium_outward__a.7-2.pdf

solo utenti autorizzati

Licenza: DRM non definito
Dimensione 579.83 kB
Formato Adobe PDF
579.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/608865
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact