Common methods to prescribe exercise intensity are based on fixed percentages of maximum rate of oxygen uptake (V˙O2max), peak work rate (WRpeak), maximal HR (HRmax). However, it is unknown how these methods compare to the current models to partition the exercise intensity spectrum. Purpose: Thus, the aim of this study was to compare contemporary gold-standard approaches for exercise prescription based on fixed percentages of maximum values to the well-established, but underutilized, "domain" schema of exercise intensity. Methods: One hundred individuals participated in the study (women, 46; men, 54). A cardiopulmonary ramp-incremental test was performed to assess V˙O2max, WRpeak, HRmax, and the lactate threshold (LT), and submaximal constant-work rate trials of 30-min duration to determine the maximal lactate steady-state (MLSS). The LT and MLSS were used to partition the intensity spectrum for each individual in three domains of intensity: moderate, heavy, and severe. Results: V˙O2max in women and men was 3.06 ± 0.41 L·min and 4.10 ± 0.56 L·min, respectively. Lactate threshold and MLSS occurred at a greater %V˙O2max and %HRmax in women compared with men (P < 0.05). The large ranges in both sexes at which LT and MLSS occurred on the basis of %V˙O2max (LT, 45%-74%; MLSS, 69%-96%), %WRpeak (LT, 23%-57%; MLSS, 44%-71%), and %HRmax (LT, 60%-90%; MLSS, 75%-97%) elicited large variability in the number of individuals distributed in each domain at the fixed-percentages examined. Conclusions: Contemporary gold-standard methods for exercise prescription based on fixed-percentages of maximum values conform poorly to exercise intensity domains and thus do not adequately control the metabolic stimulus.

A critical evaluation of current methods for exercise prescription in women and men

Iannetta D;
2020-01-01

Abstract

Common methods to prescribe exercise intensity are based on fixed percentages of maximum rate of oxygen uptake (V˙O2max), peak work rate (WRpeak), maximal HR (HRmax). However, it is unknown how these methods compare to the current models to partition the exercise intensity spectrum. Purpose: Thus, the aim of this study was to compare contemporary gold-standard approaches for exercise prescription based on fixed percentages of maximum values to the well-established, but underutilized, "domain" schema of exercise intensity. Methods: One hundred individuals participated in the study (women, 46; men, 54). A cardiopulmonary ramp-incremental test was performed to assess V˙O2max, WRpeak, HRmax, and the lactate threshold (LT), and submaximal constant-work rate trials of 30-min duration to determine the maximal lactate steady-state (MLSS). The LT and MLSS were used to partition the intensity spectrum for each individual in three domains of intensity: moderate, heavy, and severe. Results: V˙O2max in women and men was 3.06 ± 0.41 L·min and 4.10 ± 0.56 L·min, respectively. Lactate threshold and MLSS occurred at a greater %V˙O2max and %HRmax in women compared with men (P < 0.05). The large ranges in both sexes at which LT and MLSS occurred on the basis of %V˙O2max (LT, 45%-74%; MLSS, 69%-96%), %WRpeak (LT, 23%-57%; MLSS, 44%-71%), and %HRmax (LT, 60%-90%; MLSS, 75%-97%) elicited large variability in the number of individuals distributed in each domain at the fixed-percentages examined. Conclusions: Contemporary gold-standard methods for exercise prescription based on fixed-percentages of maximum values conform poorly to exercise intensity domains and thus do not adequately control the metabolic stimulus.
File in questo prodotto:
File Dimensione Formato  
A Critical Evaluation of Current Methods for exercise prescription in women and men.pdf

gestori archivio

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/605272
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact