Objectives: A breaking-point in the near-infrared spectroscopy (NIRS)-derived deoxygenated haemoglobin ([HHb]) profile towards the end of a ramp incremental (RI) cycling test has been associated to the respiratory compensation point (RCP). Despite the physiological value of this measure, its repeatability remains unknown. The aim was to examine the repeatability of the [HHb] breaking-point ([HHb]BP) and its association to RCP during a RI cycling test. Design: A repeated measures design was performed on 11 males (30.5±8.4 year; 76.5±8.4kg) and 4 females (30.5±5.9 year; 61.9±4.4 Kg). Methods: Gas exchange and NIRS [HHb] data were collected during RI tests performed on two different days separated by 48h. The [HHb]BP and the RCP were determined and compared for each trial. Results: The [HHb]BP and the respiratory compensation point (RCP) occurred at the same VO2 in test 1 and test 2 ([HHb]BP: 3.49±0.52Lmin-1 test 1; 3.48±0.45Lmin-1 test 2; RCP: 3.38±0.40Lmin-1 test 1; 3.38±0.44Lmin-1 test 2) (P>0.05). The VO2 associated with the [HHb]BP and the VO2 at RCP were not significantly different from each other either in test 1 as well as in test 2 (P>0.05). Neither test 1 nor test 2 showed significant mean average error between the VO2 at the [HHb]BP and RCP using Bland & Altman plots. Conclusions: The [HHb]BP is a repeatable measure that consistently occurs towards the end of a RI test. The association between the [HHb]BP and the RCP reinforces the idea that these parameters may share similar mechanistic basis.

The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains

Iannetta D;
2017-01-01

Abstract

Objectives: A breaking-point in the near-infrared spectroscopy (NIRS)-derived deoxygenated haemoglobin ([HHb]) profile towards the end of a ramp incremental (RI) cycling test has been associated to the respiratory compensation point (RCP). Despite the physiological value of this measure, its repeatability remains unknown. The aim was to examine the repeatability of the [HHb] breaking-point ([HHb]BP) and its association to RCP during a RI cycling test. Design: A repeated measures design was performed on 11 males (30.5±8.4 year; 76.5±8.4kg) and 4 females (30.5±5.9 year; 61.9±4.4 Kg). Methods: Gas exchange and NIRS [HHb] data were collected during RI tests performed on two different days separated by 48h. The [HHb]BP and the RCP were determined and compared for each trial. Results: The [HHb]BP and the respiratory compensation point (RCP) occurred at the same VO2 in test 1 and test 2 ([HHb]BP: 3.49±0.52Lmin-1 test 1; 3.48±0.45Lmin-1 test 2; RCP: 3.38±0.40Lmin-1 test 1; 3.38±0.44Lmin-1 test 2) (P>0.05). The VO2 associated with the [HHb]BP and the VO2 at RCP were not significantly different from each other either in test 1 as well as in test 2 (P>0.05). Neither test 1 nor test 2 showed significant mean average error between the VO2 at the [HHb]BP and RCP using Bland & Altman plots. Conclusions: The [HHb]BP is a repeatable measure that consistently occurs towards the end of a RI test. The association between the [HHb]BP and the RCP reinforces the idea that these parameters may share similar mechanistic basis.
File in questo prodotto:
File Dimensione Formato  
The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains, Iannetta.pdf

gestori archivio

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 628.18 kB
Formato Adobe PDF
628.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/605265
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact