During exhaustive ramp-incremental cycling tests, the incidence of O2 uptake (V̇o2) plateaus is low. To verify the attainment of maximum V̇o2 (V̇o2max), it is recommended that a trial at a power output (PO) corresponding to 110% of the ramp-derived peak (POpeak) is performed. It remains unclear whether verification trials set at this PO can be tolerated for long enough to allow attainment of V̇o2max. Eleven recreationally trained individuals performed five ramp tests of varying slope (5, 10, 15, 25, and 30 W/min), each followed, in series, by two verification trials: the first at 110% POpeak of the 25 W/min ramp and the second at 110% POpeak attained in the preceding ramp test. Exercise duration of the first verification trial was on average 81 ± 15 s (CV = 9 ± 3%) versus 162 ± 32, 121 ± 24, 103 ± 15, and 73 ± 10 s for the second verification trials at 110% of POpeak of the 5, 10, 15, and 30 W/min ramp tests, respectively (P < 0.05). Compared with the highest V̇o2 recorded during ramp tests, V̇o2 from the subsequent verification trials was not different for the 5, 10, and 15 W/min ramp tests (P > 0.05) but was lower for the 25 and 30 W/min ramp tests (P < 0.05). Verification trials at 110% POpeak of rapidly incrementing ramp tests (i.e., 25 W/min) were not sustained for long enough to allow the attainment of V̇o2max. With commonly used rapidly incrementing ramp tests engendering exhaustion within 8-12 min, verification trials less than POpeak should be preferred as they can be sustained sufficiently long to allow the attainment of V̇o2max.

Evaluating the suitability of supra-POpeak verification trials after ramp-incremental exercise to confirm attainment of maximum O2 uptake

Iannetta D;
2020-01-01

Abstract

During exhaustive ramp-incremental cycling tests, the incidence of O2 uptake (V̇o2) plateaus is low. To verify the attainment of maximum V̇o2 (V̇o2max), it is recommended that a trial at a power output (PO) corresponding to 110% of the ramp-derived peak (POpeak) is performed. It remains unclear whether verification trials set at this PO can be tolerated for long enough to allow attainment of V̇o2max. Eleven recreationally trained individuals performed five ramp tests of varying slope (5, 10, 15, 25, and 30 W/min), each followed, in series, by two verification trials: the first at 110% POpeak of the 25 W/min ramp and the second at 110% POpeak attained in the preceding ramp test. Exercise duration of the first verification trial was on average 81 ± 15 s (CV = 9 ± 3%) versus 162 ± 32, 121 ± 24, 103 ± 15, and 73 ± 10 s for the second verification trials at 110% of POpeak of the 5, 10, 15, and 30 W/min ramp tests, respectively (P < 0.05). Compared with the highest V̇o2 recorded during ramp tests, V̇o2 from the subsequent verification trials was not different for the 5, 10, and 15 W/min ramp tests (P > 0.05) but was lower for the 25 and 30 W/min ramp tests (P < 0.05). Verification trials at 110% POpeak of rapidly incrementing ramp tests (i.e., 25 W/min) were not sustained for long enough to allow the attainment of V̇o2max. With commonly used rapidly incrementing ramp tests engendering exhaustion within 8-12 min, verification trials less than POpeak should be preferred as they can be sustained sufficiently long to allow the attainment of V̇o2max.
File in questo prodotto:
File Dimensione Formato  
Evaluating the suitability of supra-POpeak verification trials,Iannetta.pdf

gestori archivio

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.19 MB
Formato Adobe PDF
1.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/605254
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact