The aim of the research presented in this article is to select best internal standard for use in the direct routine analysis of L series elements concentration in water samples by applying the Total Reflection X-ray Fluorescence (TXRF) technique. In the study, aqueous reference materials were used to determine detection limits of the following potentially toxic elements: Pd, Ag, Cd, In, Sn, Sb, Ba, Nd, Gd, Er, Ta, W, Tl, Pb, and Bi. The elements were in the form of: monoelemental, two-elemental (Ba and Ti, W and Cu, Pb and As), and multielemental solutions with different concentrations of elements. The detection limits of chemical elements were analyzed using various internal standards (Co, Ga, Nd, and Sr), and the TXRF spectrometers with the Mo-anode and W-anode X-ray tubes. For the analyzed L series elements, the detection limits, normalized to the same measurement time (t = 1000 s), were calculated. Finally, the internal standards were proposed to analyze the studied elements for two different X-ray sources (the Mo-anode and W-anode X-ray tubes). The detection limits were also discussed with respect to the ISO 20289:2018 standard. Based on the measurements, the relative sensitivities were calculated for each of the applied TXRF spectrometers.

Importance of internal standard selection in direct routine determination of L series elements concentration in water samples by application of the total reflection X-ray fluorescence technique

Bilo F.;Borgese L.
Writing – Review & Editing
2024-01-01

Abstract

The aim of the research presented in this article is to select best internal standard for use in the direct routine analysis of L series elements concentration in water samples by applying the Total Reflection X-ray Fluorescence (TXRF) technique. In the study, aqueous reference materials were used to determine detection limits of the following potentially toxic elements: Pd, Ag, Cd, In, Sn, Sb, Ba, Nd, Gd, Er, Ta, W, Tl, Pb, and Bi. The elements were in the form of: monoelemental, two-elemental (Ba and Ti, W and Cu, Pb and As), and multielemental solutions with different concentrations of elements. The detection limits of chemical elements were analyzed using various internal standards (Co, Ga, Nd, and Sr), and the TXRF spectrometers with the Mo-anode and W-anode X-ray tubes. For the analyzed L series elements, the detection limits, normalized to the same measurement time (t = 1000 s), were calculated. Finally, the internal standards were proposed to analyze the studied elements for two different X-ray sources (the Mo-anode and W-anode X-ray tubes). The detection limits were also discussed with respect to the ISO 20289:2018 standard. Based on the measurements, the relative sensitivities were calculated for each of the applied TXRF spectrometers.
File in questo prodotto:
File Dimensione Formato  
2024_Internal standard selection_SAB.pdf

gestori archivio

Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 803.34 kB
Formato Adobe PDF
803.34 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/600367
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact