The recovery of livestock manure, rich in nutrients, as fertilizer in agriculture, could pose the risk of an excessive load of nitrogen on the soil. Ammonia stripping is one of the available technologies for reducing the amount of nitrogen in the digestate obtained by the anaerobic digestion of manure. The study investigated the performance and energy consumption of a full-scale ammonia-stripping plant, equipped with a bubble reactor and working without the use of any alkaline reagent under semi-batch conditions. Stripping tests were conducted on the liquid fraction of the digestate, studying the current and optimized operative conditions of the plant. The main variables influencing the process were pH, temperature, airflow, and feed characteristics. In the experimental tests, the pH spontaneously increased to 10, without dosing basifying agents. Higher temperatures favoured the stripping process, the higher tested value being 68 °C. The airflow was kept equal to 15 Nm3 h−1 m−3digestate in the pre-stripping and to 60 Nm3 h−1 m−3digestate in the stripping reactors, during all tests. The energy requirement was completely satisfied by the CHP (combined heat and power) unit fed with the biogas produced by manure digestion. Results showed anaerobic digestion coupled with stripping to be a suitable solution for removing up to 81% of the ammonium with neither external energy input nor reagent dosage.

Ammonia Recovery from Livestock Manure Digestate through an Air-Bubble Stripping Reactor: Evaluation of Performance and Energy Balance

Abba A.;Domini M.;Pedrazzani R.;Bertanza G.
2023-01-01

Abstract

The recovery of livestock manure, rich in nutrients, as fertilizer in agriculture, could pose the risk of an excessive load of nitrogen on the soil. Ammonia stripping is one of the available technologies for reducing the amount of nitrogen in the digestate obtained by the anaerobic digestion of manure. The study investigated the performance and energy consumption of a full-scale ammonia-stripping plant, equipped with a bubble reactor and working without the use of any alkaline reagent under semi-batch conditions. Stripping tests were conducted on the liquid fraction of the digestate, studying the current and optimized operative conditions of the plant. The main variables influencing the process were pH, temperature, airflow, and feed characteristics. In the experimental tests, the pH spontaneously increased to 10, without dosing basifying agents. Higher temperatures favoured the stripping process, the higher tested value being 68 °C. The airflow was kept equal to 15 Nm3 h−1 m−3digestate in the pre-stripping and to 60 Nm3 h−1 m−3digestate in the stripping reactors, during all tests. The energy requirement was completely satisfied by the CHP (combined heat and power) unit fed with the biogas produced by manure digestion. Results showed anaerobic digestion coupled with stripping to be a suitable solution for removing up to 81% of the ammonium with neither external energy input nor reagent dosage.
File in questo prodotto:
File Dimensione Formato  
energies-16-01643-v3 (1).pdf

accesso aperto

Tipologia: Full Text
Licenza: Creative commons
Dimensione 1.83 MB
Formato Adobe PDF
1.83 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/589428
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact