Purpose To report a case of sutureless scleral-fixated (SSF) Carlevale intraocular lens (IOL) opacification following Descemet stripping automated endothelial keratoplasty (DSAEK) surgery. Methods An 82-year-old man underwent combined SSF Carlevale IOL implant and DSAEK surgery for aphakic endothelial decompensation. Surgery was uneventful, while the postoperative period was complicated by multiple graft detachments requiring re-bubbling. After four re-bubbling procedures, the corneal graft attached and cleared over time. Results 29 months after combined SSF IOL implant and DSAEK surgery, the patient presented with decreased vision due to IOL opacification affecting the visual axis. Conclusion Although combined SSF IOL and DSAEK surgery is an overall safe and effective procedure for aphakic endothelial decompensation, risk of IOL opacification due to anterior chamber air injection is higher when using hydrophilic IOLs and in cases requiring multiple re-bubbling, therefore, intraocular lens material should be chosen after considering the risks and benefits.
Carlevale intraocular lens opacification after Descemet stripping automated endothelial keratoplasty
Ferrara, Mariantonia;Romano, Davide;Romano, Vito
2022-01-01
Abstract
Purpose To report a case of sutureless scleral-fixated (SSF) Carlevale intraocular lens (IOL) opacification following Descemet stripping automated endothelial keratoplasty (DSAEK) surgery. Methods An 82-year-old man underwent combined SSF Carlevale IOL implant and DSAEK surgery for aphakic endothelial decompensation. Surgery was uneventful, while the postoperative period was complicated by multiple graft detachments requiring re-bubbling. After four re-bubbling procedures, the corneal graft attached and cleared over time. Results 29 months after combined SSF IOL implant and DSAEK surgery, the patient presented with decreased vision due to IOL opacification affecting the visual axis. Conclusion Although combined SSF IOL and DSAEK surgery is an overall safe and effective procedure for aphakic endothelial decompensation, risk of IOL opacification due to anterior chamber air injection is higher when using hydrophilic IOLs and in cases requiring multiple re-bubbling, therefore, intraocular lens material should be chosen after considering the risks and benefits.File | Dimensione | Formato | |
---|---|---|---|
Carlevale opacification.pdf
accesso aperto
Tipologia:
Full Text
Licenza:
Non specificato
Dimensione
939.72 kB
Formato
Adobe PDF
|
939.72 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.