The release of chromium, nickel, and manganese from knives stainless steel produced in Italy and People's Republic of China was investigated with the aim to check their quality and compliance with Italian Ministerial Decree 21.03.73, which is the most detailed text for the hygiene regulation of packaging, containers, and tools intended for food contact. Temperature effect on metal release is investigated in 18 sets of knives. Tests are performed by simulating discontinuous contact using a 3% glacial acetic acid solution in distilled water at 50 degrees C and 100 degrees C. Chromium, nickel, and manganese quantification is performed by total reflection X-Ray fluorescence. Chemical composition highlights low sulphur content, and most of them belong to the American Iron and Steel Institute (AISI) 420 type A stainless steel group. Tests performed at 100 degrees C revealed higher concentration of released metals. Only three knives tested at 100 degrees C exceed the limit of 100 mu g L-1.

Metals release from stainless steel knives in simulated food contact

Boniardi, Marco;Bilo, Fabjola;Borgese, Laura;Cirelli, Paola;Depero, Laura E
2022-01-01

Abstract

The release of chromium, nickel, and manganese from knives stainless steel produced in Italy and People's Republic of China was investigated with the aim to check their quality and compliance with Italian Ministerial Decree 21.03.73, which is the most detailed text for the hygiene regulation of packaging, containers, and tools intended for food contact. Temperature effect on metal release is investigated in 18 sets of knives. Tests are performed by simulating discontinuous contact using a 3% glacial acetic acid solution in distilled water at 50 degrees C and 100 degrees C. Chromium, nickel, and manganese quantification is performed by total reflection X-Ray fluorescence. Chemical composition highlights low sulphur content, and most of them belong to the American Iron and Steel Institute (AISI) 420 type A stainless steel group. Tests performed at 100 degrees C revealed higher concentration of released metals. Only three knives tested at 100 degrees C exceed the limit of 100 mu g L-1.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/566964
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact