Single-molecule detection at a nanometric interface in a femtomolar solution, can take weeks as the encounter rate between the diffusing molecule to be detected and the transducing nanodevice is negligibly small. On the other hand, several experiments prove that macroscopic label-free sensors based on field-effect-transistors, engaging micrometric or millimetric detecting interfaces are capable to assay a single-molecule in a large volume within few minutes. The present work demonstrates why at least a single molecule out of a few diffusing in a 100 mu L volume has a high probability to hit a large capturing and detecting electronic interface. To this end, sensing data, measured with an electrolyte-gated FET whose gate is functionalized with 10(12) capturing anti-immunoglobulin G, are here provided along with a Brownian diffusion-based modeling. The EG-FET assays solutions down to some tens of zM in concentrations with volumes ranging from 25 mu L to 1 mL in which the functionalized gates are incubated for times ranging from 30 s to 20 min. The high level of accordance between the experimental data and a model based on the Einstein's diffusion-theory proves how the single-molecule detection process at large-capturing interfaces is controlled by Brownian diffusion and yet is highly probable and fast.

Why a Diffusing Single-Molecule can be Detected in Few Minutes by a Large Capturing Bioelectronic Interface

Torricelli, Fabrizio;Torsi, Luisa
2022-01-01

Abstract

Single-molecule detection at a nanometric interface in a femtomolar solution, can take weeks as the encounter rate between the diffusing molecule to be detected and the transducing nanodevice is negligibly small. On the other hand, several experiments prove that macroscopic label-free sensors based on field-effect-transistors, engaging micrometric or millimetric detecting interfaces are capable to assay a single-molecule in a large volume within few minutes. The present work demonstrates why at least a single molecule out of a few diffusing in a 100 mu L volume has a high probability to hit a large capturing and detecting electronic interface. To this end, sensing data, measured with an electrolyte-gated FET whose gate is functionalized with 10(12) capturing anti-immunoglobulin G, are here provided along with a Brownian diffusion-based modeling. The EG-FET assays solutions down to some tens of zM in concentrations with volumes ranging from 25 mu L to 1 mL in which the functionalized gates are incubated for times ranging from 30 s to 20 min. The high level of accordance between the experimental data and a model based on the Einstein's diffusion-theory proves how the single-molecule detection process at large-capturing interfaces is controlled by Brownian diffusion and yet is highly probable and fast.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/566049
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 16
social impact