In this study, the physiological response of a sensitive lichen species (Evernia prunastri) exposed for three months in a complex urban area (Milan, Italy) was evaluated in order to verify if the air pollution abatement measures adopted over the years resulted in a suitable air quality for the survival of this sensitive species. Parameters investigated rely on the photosynthetic activity of the photobiont (Fv/Fm, PIabs, and OJIP curves), damage to mycobiont (membrane damage and antiradical activity), and the production of secondary metabolites involved in the protective functions of the organisms. Results showed that although air quality in Milan still suffers from heavy pollution from PM and NOx, the overall situation is not as severe as to induce the death of this sensitive biomonitor, at least in the short term. Nevertheless, the vital status of the samples exposed in the study area showed a significant impairment compared to that of samples exposed in a control area, indicating that the current air quality in Milan still prevents the optimal survival of E. prunastri.

Biological Effects of Air Pollution on Sensitive Bioindicators: A Case Study from Milan, Italy

Contardo, Tania;
2021-01-01

Abstract

In this study, the physiological response of a sensitive lichen species (Evernia prunastri) exposed for three months in a complex urban area (Milan, Italy) was evaluated in order to verify if the air pollution abatement measures adopted over the years resulted in a suitable air quality for the survival of this sensitive species. Parameters investigated rely on the photosynthetic activity of the photobiont (Fv/Fm, PIabs, and OJIP curves), damage to mycobiont (membrane damage and antiradical activity), and the production of secondary metabolites involved in the protective functions of the organisms. Results showed that although air quality in Milan still suffers from heavy pollution from PM and NOx, the overall situation is not as severe as to induce the death of this sensitive biomonitor, at least in the short term. Nevertheless, the vital status of the samples exposed in the study area showed a significant impairment compared to that of samples exposed in a control area, indicating that the current air quality in Milan still prevents the optimal survival of E. prunastri.
File in questo prodotto:
File Dimensione Formato  
Physiology Milan.pdf

gestori archivio

Dimensione 2.78 MB
Formato Adobe PDF
2.78 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/562157
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact