PURPOSE: The aim of this study was to describe a novel technique for descemetorhexis that combines the advantages of stable anterior chamber (AC) associated with ophthalmic viscosurgical devices and optimal surgical visualization seen with air to overcome the issues of poor Descemet membrane (DM) visibility or AC instability when each is used alone. METHODS: This study is a description of a new surgical approach. RESULTS: We describe a new technique for performing descemetorhexis. The simultaneous presence of cohesive ophthalmic viscosurgical device and air in the AC offers optimal DM visualization and guarantees a stable AC during this surgical step. It does not require an additional incision for an AC maintainer. CONCLUSIONS: The described technique may facilitate the surgical step of descemetorhexis, offering improved AC stability and better visualization of the DM. It may reduce early postoperative graft detachment due to the presence of residues of the recipient's diseased DM.

Novel Technique for Descemetorhexis Under Ophthalmic Viscosurgical Devices and Air

Romano V.
2021-01-01

Abstract

PURPOSE: The aim of this study was to describe a novel technique for descemetorhexis that combines the advantages of stable anterior chamber (AC) associated with ophthalmic viscosurgical devices and optimal surgical visualization seen with air to overcome the issues of poor Descemet membrane (DM) visibility or AC instability when each is used alone. METHODS: This study is a description of a new surgical approach. RESULTS: We describe a new technique for performing descemetorhexis. The simultaneous presence of cohesive ophthalmic viscosurgical device and air in the AC offers optimal DM visualization and guarantees a stable AC during this surgical step. It does not require an additional incision for an AC maintainer. CONCLUSIONS: The described technique may facilitate the surgical step of descemetorhexis, offering improved AC stability and better visualization of the DM. It may reduce early postoperative graft detachment due to the presence of residues of the recipient's diseased DM.
File in questo prodotto:
File Dimensione Formato  
Novel Technique for Descemetorhexis Under Ophthalmic Viscosurgical Devices and Air (Cornea 2021).pdf

gestori archivio

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 133.65 kB
Formato Adobe PDF
133.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/555281
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact