Objective of the work is to investigate stress and deformation that conrneal tissue and donor graft undergo during endothelial keratoplasty. In order to attach the donor graft to the cornea, different air bubble pressure profiles acting on the graft are considered. This study is carried out by employing a three-dimensional nonlinear finite element methodology, combined with a contact algorithm. The ocular tissues are treated as isotropic, hyper-elastic and nearly-incompressible materials. The contact algorithm, based on the penalty-based node-to-surface approach, is used to model the donor graft-corneal interface region. First, the proposed computational methodology is tested against benchmark data for bending of the plates over a cylinder. Then, the influence of geometrical and material parameters of the graft on the corneal contact-structural response is investigated. The results are presented in terms of Von Mises stress intensity, displacement and mean contact force. Results clearly indicate that the air bubble pressure plays a key role in the corneal stress and strain, as well as graft stiffness and thickness.

A novel numerical modelling approach for keratoplasty eye procedure

Romano V.;
2019-01-01

Abstract

Objective of the work is to investigate stress and deformation that conrneal tissue and donor graft undergo during endothelial keratoplasty. In order to attach the donor graft to the cornea, different air bubble pressure profiles acting on the graft are considered. This study is carried out by employing a three-dimensional nonlinear finite element methodology, combined with a contact algorithm. The ocular tissues are treated as isotropic, hyper-elastic and nearly-incompressible materials. The contact algorithm, based on the penalty-based node-to-surface approach, is used to model the donor graft-corneal interface region. First, the proposed computational methodology is tested against benchmark data for bending of the plates over a cylinder. Then, the influence of geometrical and material parameters of the graft on the corneal contact-structural response is investigated. The results are presented in terms of Von Mises stress intensity, displacement and mean contact force. Results clearly indicate that the air bubble pressure plays a key role in the corneal stress and strain, as well as graft stiffness and thickness.
File in questo prodotto:
File Dimensione Formato  
A novel numerical modelling approach for keratoplasty eye procedure (Biomech 2019).pdf

gestori archivio

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 4.25 MB
Formato Adobe PDF
4.25 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/555266
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact