In September 2018 in Brescia province, northern Italy, an outbreak of Legionnaires' disease (LD) caused by Legionella pneumophila serogroup 2 (Lp2) occurred. The 33 cases (two fatal) resided in seven municipalities along the Chiese river. All cases were negative by urinary antigen test (UAT) and most were diagnosed by real-time PCR and serology. In only three cases, respiratory sample cultures were positive, and Lp2 was identified and typed as sequence type (ST)1455. In another three cases, nested sequence-based typing was directly applied to respiratory samples, which provided allelic profiles highly similar to ST1455. An environmental investigation was undertaken immediately and water samples were collected from private homes, municipal water systems, cooling towers and the river. Overall, 533 environmental water samples were analysed and 34 were positive for Lp. Of these, only three samples, all collected from the Chiese river, were Lp2 ST1455. If and how the river water could have been aerosolised causing the LD cases remains unexplained. This outbreak, the first to our knowledge caused by Lp2, highlights the limits of UAT for LD diagnosis, underlining the importance of adopting multiple tests to ensure that serogroups other than serogroup 1, as well as other Legionella species, are identified.

A community-acquired Legionnaires' disease outbreak caused by Legionella pneumophila serogroup 2: An uncommon event, Italy, August to October 2018

Giagulli C.;Caruso A.;
2021-01-01

Abstract

In September 2018 in Brescia province, northern Italy, an outbreak of Legionnaires' disease (LD) caused by Legionella pneumophila serogroup 2 (Lp2) occurred. The 33 cases (two fatal) resided in seven municipalities along the Chiese river. All cases were negative by urinary antigen test (UAT) and most were diagnosed by real-time PCR and serology. In only three cases, respiratory sample cultures were positive, and Lp2 was identified and typed as sequence type (ST)1455. In another three cases, nested sequence-based typing was directly applied to respiratory samples, which provided allelic profiles highly similar to ST1455. An environmental investigation was undertaken immediately and water samples were collected from private homes, municipal water systems, cooling towers and the river. Overall, 533 environmental water samples were analysed and 34 were positive for Lp. Of these, only three samples, all collected from the Chiese river, were Lp2 ST1455. If and how the river water could have been aerosolised causing the LD cases remains unexplained. This outbreak, the first to our knowledge caused by Lp2, highlights the limits of UAT for LD diagnosis, underlining the importance of adopting multiple tests to ensure that serogroups other than serogroup 1, as well as other Legionella species, are identified.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/553450
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact