Objectives: To prospectively evaluate the accuracy of integrated [C-11]choline-PET/CT in the diagnosis of lymph-node recurrence in prostate cancer patients with biochemical failure after surgery. Methods: Since October 2002, 25 patients with biochemical recurrence (median PSA: 1.98 ng/ml), based on evidence of lymph-node metastases on [C-11]cholinePET/CT scan (21 cases) or conventional imaging (4 cases), were scheduled for either bilateral pelvic (12 cases) or both pelvic and retroperitoneal lymph-node dissection (13 patients). Results: Sixty-three nodal sites were evaluated histologically. The mean number of nodes removed and positive nodes were 21.92 +/- 16.91 (range: 4-74) and 8.84 +/- 9.65 (range: 1-31), respectively. Of the four patients with negative [C-11]choline-PET/CT and positive magnetic resonance, none had nodal metastases. Nineteen of the 21 patients (90%) with positive [C-11]choline-PET/CT had nodal metastases of prostate adenocarcinoma at histologic evaluation. A lesion-based analysis showed that [C-11]choline-PET/CT sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 64%, 90%, 86%, 72%, and 77%, respectively. The mean maximum diameter of true positive metastases was larger than false-negative ones (15.0 vs. 6.3 mm; p = 0.0004). Conclusions: [C-11]Choline-PET/CT is an accurate diagnostic tool for the detection of lymph-node metastases of recurrent prostate cancer. The low negative predictive value seems to depend on the limited capability of [C-11]choline-PET/CT to detect microscopic lesions. The high positive predictive value, even with low PSA values, provides a basis for further treatment decisions. (C) 2007 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Detection of lymph-node metastases with integrated [C-11]choline PET/CT in patients with PSA failure after radical retropubic prostatectomy: Results confirmed by open pelvic-retroperitoneal lymphadenectomy

Suardi N;
2007-01-01

Abstract

Objectives: To prospectively evaluate the accuracy of integrated [C-11]choline-PET/CT in the diagnosis of lymph-node recurrence in prostate cancer patients with biochemical failure after surgery. Methods: Since October 2002, 25 patients with biochemical recurrence (median PSA: 1.98 ng/ml), based on evidence of lymph-node metastases on [C-11]cholinePET/CT scan (21 cases) or conventional imaging (4 cases), were scheduled for either bilateral pelvic (12 cases) or both pelvic and retroperitoneal lymph-node dissection (13 patients). Results: Sixty-three nodal sites were evaluated histologically. The mean number of nodes removed and positive nodes were 21.92 +/- 16.91 (range: 4-74) and 8.84 +/- 9.65 (range: 1-31), respectively. Of the four patients with negative [C-11]choline-PET/CT and positive magnetic resonance, none had nodal metastases. Nineteen of the 21 patients (90%) with positive [C-11]choline-PET/CT had nodal metastases of prostate adenocarcinoma at histologic evaluation. A lesion-based analysis showed that [C-11]choline-PET/CT sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 64%, 90%, 86%, 72%, and 77%, respectively. The mean maximum diameter of true positive metastases was larger than false-negative ones (15.0 vs. 6.3 mm; p = 0.0004). Conclusions: [C-11]Choline-PET/CT is an accurate diagnostic tool for the detection of lymph-node metastases of recurrent prostate cancer. The low negative predictive value seems to depend on the limited capability of [C-11]choline-PET/CT to detect microscopic lesions. The high positive predictive value, even with low PSA values, provides a basis for further treatment decisions. (C) 2007 European Association of Urology. Published by Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/550487
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 211
social impact