This paper concerns an investigation on six large-scale Steel Fiber Reinforced Concrete (SFRC) beams tested in pure torsion. All beams had longitudinal rebars to facilitate the well-known space truss resisting mechanism. However, in order to promote economic use of the material, the transverse reinforcement (i.e. stirrups/links) was varied in the six large scale beams. The latter contained either no stirrups, or the minimum amount of transverse reinforcement (according to Eurocode 2), or hooked-end steel fibers (25 or 50 kg/m3). Material characterization were also carried out to determine the performance parameters of SFRC. The results of this study show that SFRC with a post-cracking performance class greater than 2c (according to Model Code 2010) is able to completely substitute the minimum reinforcement required for resisting torsion. In fact, the addition of steel fibers contributes to significantly increase the maximum resisting torque and maximum twist when compared to the same specimen without fibers. Moreover, SFRC provides a rather high post-cracking stiffness and a steadier development of the cracking process as compared to classical RC elements. This phenomenon improves beam behavior at serviceability limit state. The experimental results are critically discussed and compared to available analytical models as well as with other tests available into the literature.

Steel fibers for replacing minimum reinforcement in beams under torsion

Facconi L.;Minelli F.
;
Plizzari G.
2021-01-01

Abstract

This paper concerns an investigation on six large-scale Steel Fiber Reinforced Concrete (SFRC) beams tested in pure torsion. All beams had longitudinal rebars to facilitate the well-known space truss resisting mechanism. However, in order to promote economic use of the material, the transverse reinforcement (i.e. stirrups/links) was varied in the six large scale beams. The latter contained either no stirrups, or the minimum amount of transverse reinforcement (according to Eurocode 2), or hooked-end steel fibers (25 or 50 kg/m3). Material characterization were also carried out to determine the performance parameters of SFRC. The results of this study show that SFRC with a post-cracking performance class greater than 2c (according to Model Code 2010) is able to completely substitute the minimum reinforcement required for resisting torsion. In fact, the addition of steel fibers contributes to significantly increase the maximum resisting torque and maximum twist when compared to the same specimen without fibers. Moreover, SFRC provides a rather high post-cracking stiffness and a steadier development of the cracking process as compared to classical RC elements. This phenomenon improves beam behavior at serviceability limit state. The experimental results are critically discussed and compared to available analytical models as well as with other tests available into the literature.
2021
2020
Ateneo di appartenenza
PE8_3 Civil engineering, maritime/hydraulic engineering, geotechnics, waste treatment
Esperti anonimi
Inglese
Internazionale
STAMPA
54
1
1
18
18
Article number 34
Experimental tests; High strength steel fibers; Minimum reinforcement; Steel fiber reinforced concrete; Torsion in beams; Torsional rigidity
https://link.springer.com/article/10.1617/s11527-021-01615-y
no
4
info:eu-repo/semantics/article
262
Facconi, L.; Minelli, F.; Ceresa, P.; Plizzari, G.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/542654
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 26
social impact