Arsenic contamination in drinking water is a major issue in the present world. Techniques such as oxidation, precipitation and adsorption have been widely used for arsenic removal. The goal of this work is to analyze four case studies where the problem of arsenic contamination in groundwater is faced with an approach that includes experimental activities at laboratory scale and/or pilot scale. The first case study investigates the mechanisms for enhancing arsenic removal with naturally occurring Fe by the addition of an oxidizing agent (KMnO4) or a concentrated basic solution of MnO4 and AlO2. In the second case study, different experimental tests are carried out at laboratory scale in order to identify the best combination of treatments to be applied at full scale. The third case study shows the results of experimental studies followed by a full-scale upgrading for a drinking water treatment plant (DWTP) with no specific arsenic treatment in the first configuration. Last, the fourth case study investigates the performance of granular ferric oxide (GFO) with arsenic concentrations close to the Italian regulatory limit. A pilot GFO filter was installed in a DWTP. The monitoring results led to the implementation of the GFO filter at full scale.

Comparison between experimental results of different technologies for arsenic removal from water intended for human consumption

Sorlini S.
Conceptualization
2019-01-01

Abstract

Arsenic contamination in drinking water is a major issue in the present world. Techniques such as oxidation, precipitation and adsorption have been widely used for arsenic removal. The goal of this work is to analyze four case studies where the problem of arsenic contamination in groundwater is faced with an approach that includes experimental activities at laboratory scale and/or pilot scale. The first case study investigates the mechanisms for enhancing arsenic removal with naturally occurring Fe by the addition of an oxidizing agent (KMnO4) or a concentrated basic solution of MnO4 and AlO2. In the second case study, different experimental tests are carried out at laboratory scale in order to identify the best combination of treatments to be applied at full scale. The third case study shows the results of experimental studies followed by a full-scale upgrading for a drinking water treatment plant (DWTP) with no specific arsenic treatment in the first configuration. Last, the fourth case study investigates the performance of granular ferric oxide (GFO) with arsenic concentrations close to the Italian regulatory limit. A pilot GFO filter was installed in a DWTP. The monitoring results led to the implementation of the GFO filter at full scale.
File in questo prodotto:
File Dimensione Formato  
WPT-EM1981 (2).pdf

solo utenti autorizzati

Descrizione: Full paper
Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 712.68 kB
Formato Adobe PDF
712.68 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/536589
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact