Objectives: To determine the quality of Doppler images of the fetal middle cerebral artery (MCA) and umbilical artery (UA) using an objective scale, and to determine the reliability of this scale, within a multicenter randomized controlled trial (Revealed versus concealed criteria for placental insufficiency in unselected obstetric population in late pregnancy (Ratio37)). Methods: The Ratio37 trial is an ongoing randomized, open-label, multicenter controlled study of women with a low-risk pregnancy recruited at 20 weeks. Doppler measurements of the fetal MCA and UA were performed at 37 weeks. Twenty patients from each of the six participating centers were selected randomly, with two images evaluated per patient (one each for the MCA and UA). The quality of a total of 240 images was evaluated by six experts, scored on an objective scale of six items. Inter- and intrarater reliability was assessed using the Fleiss-modified kappa statistic for ordinal scales. Results: On average, 89.2% of MCA images and 85.0% of UA images were rated as being of perfect (score of 6) or almost perfect (score of 5) quality. Kappa values for intrarater reliability of quality assessment were 0.90 (95% CI, 0.88–0.92) and 0.90 (95% CI, 0.88–0.93) for the MCA and UA, respectively. The corresponding inter-rater reliability values were 0.85 (95% CI, 0.81–0.89) and 0.84 (95% CI, 0.80–0.89), respectively. Conclusion: The quality of MCA and UA Doppler ultrasound images can be evaluated reliably using an objective scale. Over 85% of images, which were obtained by operators from a broad range of clinical practices within a multicenter study, were rated as being of perfect or almost perfect quality. Intra- and inter-rater reliability of quality assessment was very good. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

Quality assessment of fetal middle cerebral and umbilical artery Doppler images using an objective scale within an international randomized controlled trial

Prefumo F.;
2020-01-01

Abstract

Objectives: To determine the quality of Doppler images of the fetal middle cerebral artery (MCA) and umbilical artery (UA) using an objective scale, and to determine the reliability of this scale, within a multicenter randomized controlled trial (Revealed versus concealed criteria for placental insufficiency in unselected obstetric population in late pregnancy (Ratio37)). Methods: The Ratio37 trial is an ongoing randomized, open-label, multicenter controlled study of women with a low-risk pregnancy recruited at 20 weeks. Doppler measurements of the fetal MCA and UA were performed at 37 weeks. Twenty patients from each of the six participating centers were selected randomly, with two images evaluated per patient (one each for the MCA and UA). The quality of a total of 240 images was evaluated by six experts, scored on an objective scale of six items. Inter- and intrarater reliability was assessed using the Fleiss-modified kappa statistic for ordinal scales. Results: On average, 89.2% of MCA images and 85.0% of UA images were rated as being of perfect (score of 6) or almost perfect (score of 5) quality. Kappa values for intrarater reliability of quality assessment were 0.90 (95% CI, 0.88–0.92) and 0.90 (95% CI, 0.88–0.93) for the MCA and UA, respectively. The corresponding inter-rater reliability values were 0.85 (95% CI, 0.81–0.89) and 0.84 (95% CI, 0.80–0.89), respectively. Conclusion: The quality of MCA and UA Doppler ultrasound images can be evaluated reliably using an objective scale. Over 85% of images, which were obtained by operators from a broad range of clinical practices within a multicenter study, were rated as being of perfect or almost perfect quality. Intra- and inter-rater reliability of quality assessment was very good. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/536203
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact