An innovative space-conditioning system is proposed and a life-cycle assessment (LCA) is presented. The layout is obtained starting from a ground-source heat pump system (GSHP) and includes upstream thermal storage (TS). A prototype of the system, implemented following this new approach, is currently in use for space heating and cooling of an industrial building. As a result of the TS designed to decouple the geothermal side from the heat-pump side, the system is able to provide the required thermal energy to the building with a reduced-size geothermal installation (i.e., shorter/fewer boreholes (BHs)). The performance was monitored for over 2 years, both in cooling and heating modes. A LCA study of this system is performed on the basis of specific data for implementation and operation phases. The results are given in terms of the comprehensive ReCiPe midpoint and endpoint indicator suite and are compared with literature studies of other conventional technologies for space conditioning.

Life-cycle assessment of an innovative ground-source heat pump system with upstream thermal storage

Aquino A.
Writing – Original Draft Preparation
2017-01-01

Abstract

An innovative space-conditioning system is proposed and a life-cycle assessment (LCA) is presented. The layout is obtained starting from a ground-source heat pump system (GSHP) and includes upstream thermal storage (TS). A prototype of the system, implemented following this new approach, is currently in use for space heating and cooling of an industrial building. As a result of the TS designed to decouple the geothermal side from the heat-pump side, the system is able to provide the required thermal energy to the building with a reduced-size geothermal installation (i.e., shorter/fewer boreholes (BHs)). The performance was monitored for over 2 years, both in cooling and heating modes. A LCA study of this system is performed on the basis of specific data for implementation and operation phases. The results are given in terms of the comprehensive ReCiPe midpoint and endpoint indicator suite and are compared with literature studies of other conventional technologies for space conditioning.
File in questo prodotto:
File Dimensione Formato  
Life-Cycle Assessment of an Innovative Ground-Source Heat Pump System with Upstream Thermal Storage.pdf

accesso aperto

Descrizione: articolo_principale
Tipologia: Documento in Post-print
Licenza: PUBBLICO - Creative Commons 4.0
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/534683
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 26
social impact