A novel quartz crystal resonator (QCR) sensor with a printed-on-crystal conductive coil, named sensor coil, is presented. The sensor coil electromagnetically coupled to an external readout coil allow to perform contactless interrogation of the QCR working as a stand-alone sensor unit. A frequency-domain readout technique is adopted that allows dual-harmonic operation by detecting the QCR frequencies of the fundamental and third harmonic, and offers first-order independence from the stand-off distance between the sensor and the readout unit. The QCR electrodes and sensor coil have been printed on a 330-μm-thick bare AT-cut quartz crystal exploiting the aerosol jet printing technology. The fabricated QCR sensor has reference values of the fundamental and third harmonic frequencies at 4.77 and 14.22 MHz, respectively. Distance-independent contactless operation has been demonstrated for distances up to 12 mm. The readout frequencies deviate from reference values less than 10 and 90 ppm for the fundamental and third harmonic, respectively, thus validating the proposed principle.

Quartz Crystal Resonator Sensor with Printed-on-Crystal Coil for Dual-Harmonic Electromagnetic Contactless Interrogation

Bau M.;Ferrari M.;Ferrari V.
2020-01-01

Abstract

A novel quartz crystal resonator (QCR) sensor with a printed-on-crystal conductive coil, named sensor coil, is presented. The sensor coil electromagnetically coupled to an external readout coil allow to perform contactless interrogation of the QCR working as a stand-alone sensor unit. A frequency-domain readout technique is adopted that allows dual-harmonic operation by detecting the QCR frequencies of the fundamental and third harmonic, and offers first-order independence from the stand-off distance between the sensor and the readout unit. The QCR electrodes and sensor coil have been printed on a 330-μm-thick bare AT-cut quartz crystal exploiting the aerosol jet printing technology. The fabricated QCR sensor has reference values of the fundamental and third harmonic frequencies at 4.77 and 14.22 MHz, respectively. Distance-independent contactless operation has been demonstrated for distances up to 12 mm. The readout frequencies deviate from reference values less than 10 and 90 ppm for the fundamental and third harmonic, respectively, thus validating the proposed principle.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/529095
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact