Purpose: The objective of the present study was to acquire and compare by the use of a navigation system the intra-operative flexion-extension movement of the knee performed actively by the patient and passively by the surgeon before and after a total knee arthroplasty (TKA) implantation. Methods: A cohort of 31 patients with primary knee osteoarthritis (OA), candidate for TKA underwent intra-operative kinematics assessment with a commercial navigation system before and after the definitive implant positioning of a Cruciate Retaining (CR) Mobile Bearing (MB) prostheses. The kinematical data were acquired while surgeon performed the flexion-extension movement (passive ROM - pROM), and while the patient performed it (active ROM - aROM). Differences between pre- and post- implantation and between active and passive motions, were statistically analyzed using paired Student t-tests (p = 0.05). Results: No statistically significant difference were found between aROM and pROM with paired Student t-test regarding internal-external rotation and anterior-posterior translation of the femoral component with respect to the tibia during flexion-extension movement before and after TKA implant (p > 0.05). Conclusions: Active muscle contraction seems to not significantly affect TKA kinematics. The ROM performed by the surgeon during operation resemble the movement actively performed by the patient. The clinical relevance of this study further supports the use of CAS system in performing intra-operative analysis concerning knee biomechanics.

No differences in knee kinematics between active and passive flexion-extension movement: an intra-operative kinematic analysis performed during total knee arthroplasty

Lopomo N. F.;
2020-01-01

Abstract

Purpose: The objective of the present study was to acquire and compare by the use of a navigation system the intra-operative flexion-extension movement of the knee performed actively by the patient and passively by the surgeon before and after a total knee arthroplasty (TKA) implantation. Methods: A cohort of 31 patients with primary knee osteoarthritis (OA), candidate for TKA underwent intra-operative kinematics assessment with a commercial navigation system before and after the definitive implant positioning of a Cruciate Retaining (CR) Mobile Bearing (MB) prostheses. The kinematical data were acquired while surgeon performed the flexion-extension movement (passive ROM - pROM), and while the patient performed it (active ROM - aROM). Differences between pre- and post- implantation and between active and passive motions, were statistically analyzed using paired Student t-tests (p = 0.05). Results: No statistically significant difference were found between aROM and pROM with paired Student t-test regarding internal-external rotation and anterior-posterior translation of the femoral component with respect to the tibia during flexion-extension movement before and after TKA implant (p > 0.05). Conclusions: Active muscle contraction seems to not significantly affect TKA kinematics. The ROM performed by the surgeon during operation resemble the movement actively performed by the patient. The clinical relevance of this study further supports the use of CAS system in performing intra-operative analysis concerning knee biomechanics.
File in questo prodotto:
File Dimensione Formato  
Grassi2020_JEO.pdf

solo utenti autorizzati

Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/528524
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact