Reliable tools for monitoring heat and moisture exchanger (HME) performance are in high demand by physicians, in order to assess the proper air conditioning delivered to intensive care unit (ICU) patients undergoing mechanical ventilation. To date, there is no system that comprehends all the requirements for clinical applications, in terms of performance and design. In this paper, a compact measurement system is proposed for monitoring HME performance in vivo, comparing the results with in vitro testing outcomes. The portable system presented is connected to the ventilation circuit close to the HME and assures wide compatibility with the new generation of smart devices because of its embedded Bluetooth low-energy module. Low power consumption ensures long-term monitoring capability of more than 24 h. Laboratory tests performed both in static and dynamic conditions showed rise- and fall-times for humidity measurements between 1 s and 1.8 s, compatible with many common variations in working operative conditions during mechanical ventilation.

A compact low-power wireless system for in vivo evaluation of heat and moisture exchanger performance

BELLITTI, PAOLO;BODINI, ANDREA;BORGHETTI, Michela;FILIPPINI, Matteo;Latronico, N.;Sardini, E.;Serpelloni, M.;TONELLO, Sarah
2019-01-01

Abstract

Reliable tools for monitoring heat and moisture exchanger (HME) performance are in high demand by physicians, in order to assess the proper air conditioning delivered to intensive care unit (ICU) patients undergoing mechanical ventilation. To date, there is no system that comprehends all the requirements for clinical applications, in terms of performance and design. In this paper, a compact measurement system is proposed for monitoring HME performance in vivo, comparing the results with in vitro testing outcomes. The portable system presented is connected to the ventilation circuit close to the HME and assures wide compatibility with the new generation of smart devices because of its embedded Bluetooth low-energy module. Low power consumption ensures long-term monitoring capability of more than 24 h. Laboratory tests performed both in static and dynamic conditions showed rise- and fall-times for humidity measurements between 1 s and 1.8 s, compatible with many common variations in working operative conditions during mechanical ventilation.
File in questo prodotto:
File Dimensione Formato  
A compact low-power wireless system for in vivo evaluation of heat and moisture exchanger performance.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 4.86 MB
Formato Adobe PDF
4.86 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/520919
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact