BACKGROUND: Radiotherapy is one of the standard treatments for cutaneous lymphoma and Total Skin Electrons Beam Irradiation (TSEBI) is generally used to treat diffuse cutaneous lymphoma and some cases of localized disease. Helical IMRT (HI) allows to treat complex target with optimal dose distribution and organ at risk sparing, so helical tomotherapy has been proposed as alternative technique to TSEBI but only one preliminary report has been published. METHODS: Three patients treated (from May 2013 to December 2014) with Helical IMRT, with a total dose between 24 and 30 Gy, were retrospectively evaluated. Data about dosimetric features, response and acute toxicity were registered and analyzed. Planned target coverage was compared with daily in vivo measures and dose calculation based on volumetric images used for set up evaluation as well. RESULTS: The patients had a mean measured surface fraction dose ranging from 1.54 Gy up to 2.0 Gy. A planned target dose ranging from 85 to 120% of prescription doses was obtained. All doses to Organs At Risk were within the required constraints. Particular attention was posed on "whole bone marrow" planned V10Gy, V12Gy and V20Gy values, ranging respectively between 23 and 43%, 20.1 and 38% and 9.8 and 24%. A comparison with the theoretical homologous values obtained with TSEBI has shown much lower values with TSEBI. Even if treatment was given in sequence to the skin of the upper and lower hemi-body, all the patients had anaemia, requiring blood transfusions, leukopenia and thrombocytopenia. CONCLUSION: Based on our limited results TSEBI should still be considered the standard method to treat total skin because of its pattern of acute and late toxicities and the dose distribution. In this particular case the better target coverage obtained with HI can be paid in terms of worse toxicity. Helical IMRT can instead be considered optimal in treating large, convex, cutaneous areas where it is difficult to use multiple electrons fields in relation with the clinical results and the limited and reversible toxicities.

Light and shadows of a new technique: Isphoton total-skin irradiation using helical IMRT feasible, less complex and as toxic as the electrons one?

Buglione, Michela;Spiazzi, Luigi;Urpis, Mauro;Baushi, Liliana;Pasinetti, Nadia;Borghetti, Paolo;Triggiani, Luca;Pedretti, Sara;Saiani, Federica;Fiume, Alfredo;Greco, Diana;Ciccarelli, Stefano;Moretti, Renzo;Magrini, Stefano Maria
2018-01-01

Abstract

BACKGROUND: Radiotherapy is one of the standard treatments for cutaneous lymphoma and Total Skin Electrons Beam Irradiation (TSEBI) is generally used to treat diffuse cutaneous lymphoma and some cases of localized disease. Helical IMRT (HI) allows to treat complex target with optimal dose distribution and organ at risk sparing, so helical tomotherapy has been proposed as alternative technique to TSEBI but only one preliminary report has been published. METHODS: Three patients treated (from May 2013 to December 2014) with Helical IMRT, with a total dose between 24 and 30 Gy, were retrospectively evaluated. Data about dosimetric features, response and acute toxicity were registered and analyzed. Planned target coverage was compared with daily in vivo measures and dose calculation based on volumetric images used for set up evaluation as well. RESULTS: The patients had a mean measured surface fraction dose ranging from 1.54 Gy up to 2.0 Gy. A planned target dose ranging from 85 to 120% of prescription doses was obtained. All doses to Organs At Risk were within the required constraints. Particular attention was posed on "whole bone marrow" planned V10Gy, V12Gy and V20Gy values, ranging respectively between 23 and 43%, 20.1 and 38% and 9.8 and 24%. A comparison with the theoretical homologous values obtained with TSEBI has shown much lower values with TSEBI. Even if treatment was given in sequence to the skin of the upper and lower hemi-body, all the patients had anaemia, requiring blood transfusions, leukopenia and thrombocytopenia. CONCLUSION: Based on our limited results TSEBI should still be considered the standard method to treat total skin because of its pattern of acute and late toxicities and the dose distribution. In this particular case the better target coverage obtained with HI can be paid in terms of worse toxicity. Helical IMRT can instead be considered optimal in treating large, convex, cutaneous areas where it is difficult to use multiple electrons fields in relation with the clinical results and the limited and reversible toxicities.
File in questo prodotto:
File Dimensione Formato  
13014_2018_Article_1100.pdf

accesso aperto

Tipologia: Full Text
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 2.45 MB
Formato Adobe PDF
2.45 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/513023
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 8
social impact