Purpose: To compare the retinal sensitivity after complete internal limiting membrane (ILM) peeling with that after foveal-sparing ILM peeling during vitrectomy for Type I epiretinal membrane. Methods: This was a prospective, randomized, comparative study. Thirty-eight eyes were randomized to undergo complete peeling of the ILM (CP group) or peeling with foveal sparing (FS group). The main outcome measures were foveal and perifoveal retinal sensitivity, visual acuity, and central retinal thickness. Results: Foveal retinal sensitivity showed a significant improvement in the FS group (2.82 ± 0.85 dB, P = 0.037) versus a slight drop in the CP group (-0.66 ± 0.48 dB, P = 1). Perifoveal retinal sensitivity slightly improved in both groups (0.47 ± 0.37 dB, P = 1 in the CP group and 0.79 ± 0.42 dB, P = 0.77 in the FS group), showing a similar trend without significant differences. Significant improvements were observed in both visual acuity and central retinal thickness in both groups. However, three cases in the FS group showed epiretinal membrane recurrence and required revision surgery with complete ILM removal. Conclusion: Internal limiting membrane peeling may reduce retinal sensitivity and significantly increase the incidence of microscotomas. However, the higher epiretinal membrane recurrence rate after the foveal-sparing technique limits the effectiveness of this procedure. Further studies must be conducted to determine if it is safe to leave a portion of the ILM in front of the fovea.

EPIRETINAL MEMBRANE REMOVAL WITH FOVEAL-SPARING INTERNAL LIMITING MEMBRANE PEELING A Pilot Study

Morescalchi F.;Semeraro F.
2019-01-01

Abstract

Purpose: To compare the retinal sensitivity after complete internal limiting membrane (ILM) peeling with that after foveal-sparing ILM peeling during vitrectomy for Type I epiretinal membrane. Methods: This was a prospective, randomized, comparative study. Thirty-eight eyes were randomized to undergo complete peeling of the ILM (CP group) or peeling with foveal sparing (FS group). The main outcome measures were foveal and perifoveal retinal sensitivity, visual acuity, and central retinal thickness. Results: Foveal retinal sensitivity showed a significant improvement in the FS group (2.82 ± 0.85 dB, P = 0.037) versus a slight drop in the CP group (-0.66 ± 0.48 dB, P = 1). Perifoveal retinal sensitivity slightly improved in both groups (0.47 ± 0.37 dB, P = 1 in the CP group and 0.79 ± 0.42 dB, P = 0.77 in the FS group), showing a similar trend without significant differences. Significant improvements were observed in both visual acuity and central retinal thickness in both groups. However, three cases in the FS group showed epiretinal membrane recurrence and required revision surgery with complete ILM removal. Conclusion: Internal limiting membrane peeling may reduce retinal sensitivity and significantly increase the incidence of microscotomas. However, the higher epiretinal membrane recurrence rate after the foveal-sparing technique limits the effectiveness of this procedure. Further studies must be conducted to determine if it is safe to leave a portion of the ILM in front of the fovea.
2019
2018
Ateneo di appartenenza
LS3_5 Cell differentiation, physiology and dynamics
LS5_4 Sensory systems (e.g. visual system, auditory system)
LS7_7 Surgery
Esperti anonimi
Inglese
Internazionale
STAMPA
39
11
2116
2124
9
epiretinal membrane; foveal-sparing internal limiting membrane peeling; internal limiting membrane peeling; retinal sensitivity;
Altra università italiana
no
6
info:eu-repo/semantics/article
262
Russo, A.; Morescalchi, F.; Gambicorti, E.; Cancarini, A.; Costagliola, C.; Semeraro, F.
1 Contributo su Rivista::1.1 Articolo in rivista
reserved
File in questo prodotto:
File Dimensione Formato  
RETINA 39 2116 2124 2019.pdf

gestori archivio

Descrizione: Retina 2018-2019 epiretinal membrane
Tipologia: Full Text
Licenza: DRM non definito
Dimensione 688.69 kB
Formato Adobe PDF
688.69 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/512823
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 34
social impact