In recent decades, muon imaging has found a plethora of applications in many fields. This technique succeeds to infer the density distribution of big inaccessible structures where conventional techniques cannot be used. The requirements of different applications demand specific implementations of image reconstruction algorithms for either multiple scattering or absorption-transmission data analysis, as well as noise-suppression filters and muon momentum estimators. This paper presents successful results of image reconstruction techniques applied to simulated data of some representative applications. In addition to well-known reconstruction methods, a novel approach, the so-called μCT, is proposed for the inspection of spent nuclear fuel canisters. Results obtained based on both μCT and the maximum-likelihood expectation maximization reconstruction algorithms are presented.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.

Muography of different structures using muon scattering and absorption algorithms

Bonomi, G;Donzella, A;Zenoni, A
2019-01-01

Abstract

In recent decades, muon imaging has found a plethora of applications in many fields. This technique succeeds to infer the density distribution of big inaccessible structures where conventional techniques cannot be used. The requirements of different applications demand specific implementations of image reconstruction algorithms for either multiple scattering or absorption-transmission data analysis, as well as noise-suppression filters and muon momentum estimators. This paper presents successful results of image reconstruction techniques applied to simulated data of some representative applications. In addition to well-known reconstruction methods, a novel approach, the so-called μCT, is proposed for the inspection of spent nuclear fuel canisters. Results obtained based on both μCT and the maximum-likelihood expectation maximization reconstruction algorithms are presented.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.
2019
2018
Altra università italiana
PE9_10 High energy and particles astronomy – X-rays, cosmic rays, gamma rays, neutrinos
Esperti anonimi
Inglese
Internazionale
ELETTRONICO
377
2137
20180051
18
absorption; cosmic rays; image reconstruction; maximum-likelihood expectation maximization; muon radiography; muon tomography
https://royalsocietypublishing.org/doi/10.1098/rsta.2018.0051
9
info:eu-repo/semantics/article
262
Vanini, S; Calvini, P; Checchia, P; Rigoni Garola, A; Klinger, J; Zumerle, G; Bonomi, G; Donzella, A; Zenoni, A
1 Contributo su Rivista::1.1 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
PhilTransA2018_Vanini.pdf

accesso aperto

Tipologia: Full Text
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/512522
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 37
social impact