Polyamide 12 (PA12) is used in a variety of applications when low moisture absorption, good dimensional stability, and toughness are required. Polyamide 12 is one of the polymers most frequently employed to fabricate angioplasty balloon catheters; however, its high hydrophobicity and chemical inertness require the application of coatings to make its surface more hydrophilic and biocompatible. In this work, an alternative method, based on the photochemical reaction of PA12 with a hydrophilic aromatic azide, was developed. Static and dynamic contact angle measurements evidenced that the surface modification process was able to improve PA12 wettability and that the effects were retained even after 12 months from surface treatment. Polyamide 12 modification resulted in an increase of its surface free energy, as evaluated by the van Oss, Good, and Chaudhury method. X-ray photoelectron spectroscopy confirmed the presence of the aromatic azide on PA12 surface. Finally, compliance tests showed that the modification process did not reduce the mechanical performance of balloons.
Surface modification of polyamide 12 angioplasty balloons by photochemical reaction with an aromatic azide
D'Onofrio S.;Bignotti F.
2019-01-01
Abstract
Polyamide 12 (PA12) is used in a variety of applications when low moisture absorption, good dimensional stability, and toughness are required. Polyamide 12 is one of the polymers most frequently employed to fabricate angioplasty balloon catheters; however, its high hydrophobicity and chemical inertness require the application of coatings to make its surface more hydrophilic and biocompatible. In this work, an alternative method, based on the photochemical reaction of PA12 with a hydrophilic aromatic azide, was developed. Static and dynamic contact angle measurements evidenced that the surface modification process was able to improve PA12 wettability and that the effects were retained even after 12 months from surface treatment. Polyamide 12 modification resulted in an increase of its surface free energy, as evaluated by the van Oss, Good, and Chaudhury method. X-ray photoelectron spectroscopy confirmed the presence of the aromatic azide on PA12 surface. Finally, compliance tests showed that the modification process did not reduce the mechanical performance of balloons.File | Dimensione | Formato | |
---|---|---|---|
2018-Surface modification of polyamide 12 angioplasty balloons.pdf
gestori archivio
Tipologia:
Full Text
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
240.9 kB
Formato
Adobe PDF
|
240.9 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.