Background: CHA2DS2-VASc is a validated score for predicting stroke in patients with atrial fibrillation (AF). Objective: The purpose of this study was to assess whether the CHA2DS2-VASc score can predict new-onset AF in a cohort of patients with a cardiac implantable electronic device (CIED) followed with remote monitoring. Methods: Using the database of the Home Monitoring Expert Alliance project, we selected 2410 patients with no documented AF who had received a CIED with diagnostics on atrial high rate episodes (AHREs). The primary endpoint was time to first day with cumulative AHRE burden ≥15 minutes, 5 hours, 24 hours, and ≥7 consecutive days. Results: During a median duration of 24.1(11.5–42.9) months, the incidence of AHRE increased with increasing CHA2DS2-VASc. At 6 years, occurrence of ≥15-minute AHRE was 80.2% (CHA2DS2-VASc ≤1) vs 93.7% (CHA2DS2-VASc ≥5), whereas ≥5-hour AHRE incidence was 68.4% (CHA2DS2-VASc ≤1) vs 92.5% (CHA2DS2-VASc ≥5). Occurrence of ≥24-hour and ≥7-day AHREs also increased with increasing CHA2DS2-VASc: 9.1% and 3.9% (CHA2DS2-VASc ≤1) vs 40.4% and 28.7% (CHA2DS2-VASc ≥5), respectively. Adjusted hazard ratio for unitary CHA2DS2-VASc increase ranged from 1.09 (confidence interval 1.04–1.14; P <.001) with AHRE burden ≥15 minutes to 1.26 (confidence interval 1.11–1.42; P <.001) with AHRE burden ≥7 days. At receiver operating curve analysis, CHA2DS2-VASc ≥2 was estimated to predict persistent forms of AHREs with 95.8% sensitivity but 11.7% specificity at 3 years. CHA2DS2-VASc ≥5 had 77.0% specificity but 34.6% sensitivity. Conclusion: In a CIED population with no previous diagnosis of clinical AF, AHRE incidence increased with increasing CHA2DS2-VASc score. The association was stronger with longer AHREs, but the accuracy of CHA2DS2-VASc as AHRE predictor was moderate.

Does the CHA2DS2-VASc score reliably predict atrial arrhythmias? Analysis of a nationwide database of remote monitoring data transmitted daily from cardiac implantable electronic devices

Curnis A;
2018-01-01

Abstract

Background: CHA2DS2-VASc is a validated score for predicting stroke in patients with atrial fibrillation (AF). Objective: The purpose of this study was to assess whether the CHA2DS2-VASc score can predict new-onset AF in a cohort of patients with a cardiac implantable electronic device (CIED) followed with remote monitoring. Methods: Using the database of the Home Monitoring Expert Alliance project, we selected 2410 patients with no documented AF who had received a CIED with diagnostics on atrial high rate episodes (AHREs). The primary endpoint was time to first day with cumulative AHRE burden ≥15 minutes, 5 hours, 24 hours, and ≥7 consecutive days. Results: During a median duration of 24.1(11.5–42.9) months, the incidence of AHRE increased with increasing CHA2DS2-VASc. At 6 years, occurrence of ≥15-minute AHRE was 80.2% (CHA2DS2-VASc ≤1) vs 93.7% (CHA2DS2-VASc ≥5), whereas ≥5-hour AHRE incidence was 68.4% (CHA2DS2-VASc ≤1) vs 92.5% (CHA2DS2-VASc ≥5). Occurrence of ≥24-hour and ≥7-day AHREs also increased with increasing CHA2DS2-VASc: 9.1% and 3.9% (CHA2DS2-VASc ≤1) vs 40.4% and 28.7% (CHA2DS2-VASc ≥5), respectively. Adjusted hazard ratio for unitary CHA2DS2-VASc increase ranged from 1.09 (confidence interval 1.04–1.14; P <.001) with AHRE burden ≥15 minutes to 1.26 (confidence interval 1.11–1.42; P <.001) with AHRE burden ≥7 days. At receiver operating curve analysis, CHA2DS2-VASc ≥2 was estimated to predict persistent forms of AHREs with 95.8% sensitivity but 11.7% specificity at 3 years. CHA2DS2-VASc ≥5 had 77.0% specificity but 34.6% sensitivity. Conclusion: In a CIED population with no previous diagnosis of clinical AF, AHRE incidence increased with increasing CHA2DS2-VASc score. The association was stronger with longer AHREs, but the accuracy of CHA2DS2-VASc as AHRE predictor was moderate.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/507683
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 21
social impact