The evaluation of the morphological characteristics of small resistance arteries in humans is challenging. The gold standard method is generally considered to be the measurement by wire or pressure micromyography of the media-to-lumen ratio of subcutaneous small vessels obtained by local biopsies. However, noninvasive techniques for the evaluation of retinal arterioles were recently proposed; in particular, two approaches, scanning laser Doppler flowmetry (SLDF) and adaptive optics, seem to provide useful information; both of them provide an estimation of the wall-to-lumen ratio (WLR) of retinal arterioles. Moreover, a noninvasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of these three noninvasive techniques in the same population was previously performed; in particular, adaptive optics was never validated against micromyography.

Comparison between invasive and noninvasive techniques of evaluation of microvascular structural alterations

De Ciuceis, Carolina;Agabiti Rosei, Claudia;Caletti, Stefano;Trapletti, Valentina;Coschignano, Maria A;Tiberio, Guido A M;Duse, Sarah;Docchio, Franco;Pasinetti, Simone;Semeraro, Francesco;Porteri, Enzo;Solaini, Leonardo;Sansoni, Giovanna;Pileri, Paola;Rossini, Claudia;Mittempergher, Francesco;Portolani, Nazario;Ministrini, Silvia;Agabiti-Rosei, Enrico;Rizzoni, Damiano
2018-01-01

Abstract

The evaluation of the morphological characteristics of small resistance arteries in humans is challenging. The gold standard method is generally considered to be the measurement by wire or pressure micromyography of the media-to-lumen ratio of subcutaneous small vessels obtained by local biopsies. However, noninvasive techniques for the evaluation of retinal arterioles were recently proposed; in particular, two approaches, scanning laser Doppler flowmetry (SLDF) and adaptive optics, seem to provide useful information; both of them provide an estimation of the wall-to-lumen ratio (WLR) of retinal arterioles. Moreover, a noninvasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of these three noninvasive techniques in the same population was previously performed; in particular, adaptive optics was never validated against micromyography.
File in questo prodotto:
File Dimensione Formato  
J Hypertension 2018 - Comparison.pdf

gestori archivio

Descrizione: J hypertension 2018 - invasive and noninvasive techniques
Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 319.83 kB
Formato Adobe PDF
319.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/505668
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 28
social impact