Objective: The evaluation of the morphological characteristics of small resis-tance arteries in human beings in not easy. The gold standard is generally consid-ered to be the evaluation of the media to lumen ratio (M/L) of subcutaneous small vessels obtained by local biopsies and evaluated by wire or pressure micromyiog-raphy. However, non-invasive techniques for the evaluation of retinal arterioles were recently proposed, in particular two approaches seem to provide interesting information: scanning laser Doppler fl owmetry (SLDF) and adaptive optics (AO); both of them provide an estimation of the wall to lumen ratio (WLR) of retinal arterioles. A non-invasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of the three non-invasive techniques in the same population was previously performed, in par-ticular AO was never validated against micromyography.
COMPARISON BETWEEN THREE NON-INVASIVE TECHNIQUES OF EVALUATION MICROVASCULAR MORPHOLOGY VS. THE GOLD-STANDARD LOCALLY INVASIVE MICROMYOGRAPHY. PRELIMINARY DATA
De Ciuceis, C.;CALETTI, STEFANO;COSCHIGNANO, Maria Antonietta;Rossini, C.;Duse, S.;Docchio, F.;Pasinetti, S.;Semeraro, F.;Sansoni, G.;Rosei, C. Agabiti;Pileri, P.;Rosei, E. Agabiti;Rizzoni, D.
2017-01-01
Abstract
Objective: The evaluation of the morphological characteristics of small resis-tance arteries in human beings in not easy. The gold standard is generally consid-ered to be the evaluation of the media to lumen ratio (M/L) of subcutaneous small vessels obtained by local biopsies and evaluated by wire or pressure micromyiog-raphy. However, non-invasive techniques for the evaluation of retinal arterioles were recently proposed, in particular two approaches seem to provide interesting information: scanning laser Doppler fl owmetry (SLDF) and adaptive optics (AO); both of them provide an estimation of the wall to lumen ratio (WLR) of retinal arterioles. A non-invasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of the three non-invasive techniques in the same population was previously performed, in par-ticular AO was never validated against micromyography.File | Dimensione | Formato | |
---|---|---|---|
J Hypert abs 2017 micromyography.pdf
gestori archivio
Descrizione: micromiography 2017 abs
Tipologia:
Abstract
Licenza:
DRM non definito
Dimensione
81.01 kB
Formato
Adobe PDF
|
81.01 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Artery research abs 2017.pdf
gestori archivio
Descrizione: artery res 2017 abs
Tipologia:
Abstract
Licenza:
DRM non definito
Dimensione
220.89 kB
Formato
Adobe PDF
|
220.89 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.