The drinking water distribution system of Cremona, in the north of Italy, was monitored for 6 years (2006–2011) analyzing chlorine dioxide, chlorite, and chlorate concentrations. The software Epanet 2.0 (USEPA) was applied to the distribution system. The mixing zone of the water coming from the two drinking water treatment plants, respectively located to the west and east of the city, was estimated using the software. Propagation of chlorine dioxide, chlorite, and chlorate was simulated with the software. Measured and simulated results were compared. The results of the distribution system monitoring showed a high chlorine dioxide consumption, since residual chlorine concentration was always below 0.12 mg L1. Chlorite concentration was over 700 μg L1 for 12–16% of results in the first 2 years, for 48% of results in 2008, and for 1–8% of results from 2009 to 2011. In particular, chlorite exceeded 700 μg L1 at points of the network more distant from the treatment plants. Conversely, chlorate concentration was always below 200 μg L1. The mixing zone of the water in the distribution system was determined, and the comparison between measured and simulated concentrations showed the usefulness of the model for predicting disinfectant and by-product propagation in the distribution system.

Modeling and analysis of chlorine dioxide, chlorite, and chlorate propagation in a drinking water distribution system

SORLINI, Sabrina;BIASIBETTI, Michela;GIALDINI, Francesca;MURACA, Alessandro
2016-01-01

Abstract

The drinking water distribution system of Cremona, in the north of Italy, was monitored for 6 years (2006–2011) analyzing chlorine dioxide, chlorite, and chlorate concentrations. The software Epanet 2.0 (USEPA) was applied to the distribution system. The mixing zone of the water coming from the two drinking water treatment plants, respectively located to the west and east of the city, was estimated using the software. Propagation of chlorine dioxide, chlorite, and chlorate was simulated with the software. Measured and simulated results were compared. The results of the distribution system monitoring showed a high chlorine dioxide consumption, since residual chlorine concentration was always below 0.12 mg L1. Chlorite concentration was over 700 μg L1 for 12–16% of results in the first 2 years, for 48% of results in 2008, and for 1–8% of results from 2009 to 2011. In particular, chlorite exceeded 700 μg L1 at points of the network more distant from the treatment plants. Conversely, chlorate concentration was always below 200 μg L1. The mixing zone of the water in the distribution system was determined, and the comparison between measured and simulated concentrations showed the usefulness of the model for predicting disinfectant and by-product propagation in the distribution system.
File in questo prodotto:
File Dimensione Formato  
JWSRT_AQUA_2016.pdf

accesso aperto

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 982.39 kB
Formato Adobe PDF
982.39 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/488565
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact