Many water treatment plants (WTPs) were designed to remove ammonia, iron, and manganese simultaneously using biofilters. In some cases (especially in the Pianura Padana area, in Italy) such plants were designed without a specific treatment stage for arsenic removal because its concentration in the groundwater (i.e. 10 to 20 μg/L) was lower than the previous maximum contaminant level (MCL) of 50 μg-As/L; therefore, specific treatments for arsenic removal must be introduced or upgraded in WTPs. In this work, the results of a 19-month monitoring campaign are reported for a pilot granular ferric oxide (GFO) filter installed in an Italian WTP as a polishing stage. The aim was to investigate the performance of GFO with low arsenic concentrations. The results show that, if the groundwater arsenic concentration is close to the MCL, GFO treatment can be cost effective (approximately 80,000 bed volumes have been treated). It was confirmed that GFO can be effective for the removal of both As(III) and As(V) species.

Monitoring of a pilot GFO filter for removal of low-concentration arsenic in water

CANATO, Matteo;SORLINI, Sabrina;
2016-01-01

Abstract

Many water treatment plants (WTPs) were designed to remove ammonia, iron, and manganese simultaneously using biofilters. In some cases (especially in the Pianura Padana area, in Italy) such plants were designed without a specific treatment stage for arsenic removal because its concentration in the groundwater (i.e. 10 to 20 μg/L) was lower than the previous maximum contaminant level (MCL) of 50 μg-As/L; therefore, specific treatments for arsenic removal must be introduced or upgraded in WTPs. In this work, the results of a 19-month monitoring campaign are reported for a pilot granular ferric oxide (GFO) filter installed in an Italian WTP as a polishing stage. The aim was to investigate the performance of GFO with low arsenic concentrations. The results show that, if the groundwater arsenic concentration is close to the MCL, GFO treatment can be cost effective (approximately 80,000 bed volumes have been treated). It was confirmed that GFO can be effective for the removal of both As(III) and As(V) species.
File in questo prodotto:
File Dimensione Formato  
WPT_2016.pdf

solo utenti autorizzati

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 544.83 kB
Formato Adobe PDF
544.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/488548
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact