Critical barriers to safe and secure drinking water may include sources (e.g. groundwater contamination), treatments (e.g. treatment plants not properly operating) and/or contamination within the distribution system (infrastructure not properly maintained). The performance assessment of these systems, based on monitoring, process parameter control and experimental tests, is a viable tool for the process optimization and water quality control. The aim of this study was to define a procedure for evaluating the performance of full-scale drinking water treatment plants (DWTPs) and for defining optimal solutions for plant upgrading in order to optimize operation. The protocol is composed of four main phases (routine and intensive monitoring programmes – Phases 1 and 2; experimental studies – Phase 3; plant upgrade and optimization – Phase 4). The protocol suggested in this study was tested in a full-scale DWTP placed in the North of Italy (Mortara, Pavia). The results outline some critical aspects of the plant operation and permit the identification of feasible solutions for the DWTP upgrading in order to optimize water treatment operation.

Methodological approach for the optimization of drinking water treatment plants’ operation: a case study

SORLINI, Sabrina;
2015-01-01

Abstract

Critical barriers to safe and secure drinking water may include sources (e.g. groundwater contamination), treatments (e.g. treatment plants not properly operating) and/or contamination within the distribution system (infrastructure not properly maintained). The performance assessment of these systems, based on monitoring, process parameter control and experimental tests, is a viable tool for the process optimization and water quality control. The aim of this study was to define a procedure for evaluating the performance of full-scale drinking water treatment plants (DWTPs) and for defining optimal solutions for plant upgrading in order to optimize operation. The protocol is composed of four main phases (routine and intensive monitoring programmes – Phases 1 and 2; experimental studies – Phase 3; plant upgrade and optimization – Phase 4). The protocol suggested in this study was tested in a full-scale DWTP placed in the North of Italy (Mortara, Pavia). The results outline some critical aspects of the plant operation and permit the identification of feasible solutions for the DWTP upgrading in order to optimize water treatment operation.
File in questo prodotto:
File Dimensione Formato  
WST-EM14775R1S2.pdf

gestori archivio

Descrizione: Articolo principale
Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 429.09 kB
Formato Adobe PDF
429.09 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/476312
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 20
social impact