Introduction: The aim of the present study was to compare two obturation techniques, i.e. Thermafil® and cold lateral condensation, in order to determine which one was most easily and rapidly learnt and applied by dental students. Methods: Fifty single-rooted teeth were instrumented by the crown-down technique. Five students were requested to obturate five teeth using the Thermafil technique and five using lateral condensation. A microleakage study was performed using a 2% aqueous methylene blue dye solution. The apical portion of teeth was sectioned into six sections and evaluated under a stereomicroscope. The presence of dye microleakage was considered when assessing every section. Results: Results were processed statistically by frequence of distribution and the Mann-Whitney test. A highly significant difference (P < 0.0001) was observed between Thermafil and cold lateral condensation techniques, the former resulting in lower leakage. Conclusion: The present study, though limited and only referring to a small group, suggested that characteristics of operators and the early repeated use of a technique may influence performance.

A study on undergraduate learning of two obturation techniques: Thermafil versus lateral condensation

CERUTTI, Francesca;CERUTTI, Antonio;
2009-01-01

Abstract

Introduction: The aim of the present study was to compare two obturation techniques, i.e. Thermafil® and cold lateral condensation, in order to determine which one was most easily and rapidly learnt and applied by dental students. Methods: Fifty single-rooted teeth were instrumented by the crown-down technique. Five students were requested to obturate five teeth using the Thermafil technique and five using lateral condensation. A microleakage study was performed using a 2% aqueous methylene blue dye solution. The apical portion of teeth was sectioned into six sections and evaluated under a stereomicroscope. The presence of dye microleakage was considered when assessing every section. Results: Results were processed statistically by frequence of distribution and the Mann-Whitney test. A highly significant difference (P < 0.0001) was observed between Thermafil and cold lateral condensation techniques, the former resulting in lower leakage. Conclusion: The present study, though limited and only referring to a small group, suggested that characteristics of operators and the early repeated use of a technique may influence performance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/47220
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact