Even if pivot-shift (PS) test has been clinically used to specifically detect anterior cruciate ligament (ACL) injury, the main problem in using this combined test has been yet associated with the difficulty of clearly quantifying its outcome. The goal of this study was to describe an original non-invasive methodology used to quantify PS test, highlighting its possible clinical reliability. The method was validated on 66 consecutive unilateral ACL-injured patients. A commercial triaxial accelerometer was non-invasively mounted on patient's tibia, the corresponding 3D acceleration was acquired during PS test execution and a set of specific parameters were automatically identified on the signal to quantify the test. PS test was repeated three times on both injured and controlateral limbs. Reliability of the method was found to be good (mean intra-rater intraclass correlation coefficient was 0.79); moreover, we found that ACL-deficient knees presented statistically higher values for the identified parameters - than the controlateral healthy limbs, averagely reporting also large effect size.

An original clinical methodology for non-invasive assessment of pivot-shift test

LOPOMO, NICOLA FRANCESCO;
2012-01-01

Abstract

Even if pivot-shift (PS) test has been clinically used to specifically detect anterior cruciate ligament (ACL) injury, the main problem in using this combined test has been yet associated with the difficulty of clearly quantifying its outcome. The goal of this study was to describe an original non-invasive methodology used to quantify PS test, highlighting its possible clinical reliability. The method was validated on 66 consecutive unilateral ACL-injured patients. A commercial triaxial accelerometer was non-invasively mounted on patient's tibia, the corresponding 3D acceleration was acquired during PS test execution and a set of specific parameters were automatically identified on the signal to quantify the test. PS test was repeated three times on both injured and controlateral limbs. Reliability of the method was found to be good (mean intra-rater intraclass correlation coefficient was 0.79); moreover, we found that ACL-deficient knees presented statistically higher values for the identified parameters - than the controlateral healthy limbs, averagely reporting also large effect size.
File in questo prodotto:
File Dimensione Formato  
Lopomo2012_GCMB.pdf

solo utenti autorizzati

Descrizione: Articolo Principale
Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 236.39 kB
Formato Adobe PDF
236.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/461895
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 97
  • ???jsp.display-item.citation.isi??? 70
social impact