In vivo monitoring of human knee implants after total arthroplasty increases information concerning articular motion and loading conditions. The autonomous sensor proposed carries out force measurements in a protected environment and wirelessly transmits data directly from the inside of the implant to an external readout unit. The autonomous sensor is fully contained in the polyethylene insert. Batteries are completely eliminated; the system gathers energy from an externally applied magnetic field using a miniature coil inside the implant. The data generated from this device will provide data for new designs, techniques and implementations. The forces transmitted across the knee joint during normal human activities such as walking, running or climbing can be directly measured. Furthermore, the device can be used to improve design, refine surgical instrumentation, guide post-operative physical therapy and detect human activities that can overload the implant.

Design and test of an autonomous sensor for force measurements in human knee implants

CRESCINI, Damiano;SARDINI, Emilio;SERPELLONI, MAURO
2011-01-01

Abstract

In vivo monitoring of human knee implants after total arthroplasty increases information concerning articular motion and loading conditions. The autonomous sensor proposed carries out force measurements in a protected environment and wirelessly transmits data directly from the inside of the implant to an external readout unit. The autonomous sensor is fully contained in the polyethylene insert. Batteries are completely eliminated; the system gathers energy from an externally applied magnetic field using a miniature coil inside the implant. The data generated from this device will provide data for new designs, techniques and implementations. The forces transmitted across the knee joint during normal human activities such as walking, running or climbing can be directly measured. Furthermore, the device can be used to improve design, refine surgical instrumentation, guide post-operative physical therapy and detect human activities that can overload the implant.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S092442471000508X-main.pdf

gestori archivio

Tipologia: Abstract
Licenza: DRM non definito
Dimensione 1.83 MB
Formato Adobe PDF
1.83 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/45638
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 29
social impact