Objectives. To measure the temperature change in the pulp cavity of an extracted tooth during the polymerization of provisional resins within impression putty and polyethylene matrices. The effect of precooling the putty matrix was also evaluated. Methods. A freshly extracted premolar tooth had putty impressions recorded prior to crown preparation. Putty matrices were stored at room temperature, 4 and −12 C prior to use. A thermocouple placed in the pulp chamber recorded the temperature change every 15 s for a 10min duration during polymerization of three resins using putty and clear polyethylene matrices. Five recordings were made with each material at each storage temperature. Results. There is a temperature rise of 3.4–5.5 C when the resins were autocured in a putty matrix. When the polyvinyl matrix was used the temperature rise increased to 4.0–8.2 C (P < 0.001). The temperature rise was reduced to zero when the putty had been precooled in the fridge (P < 0.001) and reduced further following precooling in the freezer (P < 0.001). Significance. The use of a polyvinyl matrix allows higher pulp temperature rises to occur due to the exotherm from provisional resins. Lower temperatures were recorded when putty was used. The temperature rise could be eliminated when the putty was cooled at 4 C prior to reinsertion.
Temperature change in pulp cavity in vitro during the polymerization of provisional resins
GASTALDI, Giorgio;
2009-01-01
Abstract
Objectives. To measure the temperature change in the pulp cavity of an extracted tooth during the polymerization of provisional resins within impression putty and polyethylene matrices. The effect of precooling the putty matrix was also evaluated. Methods. A freshly extracted premolar tooth had putty impressions recorded prior to crown preparation. Putty matrices were stored at room temperature, 4 and −12 C prior to use. A thermocouple placed in the pulp chamber recorded the temperature change every 15 s for a 10min duration during polymerization of three resins using putty and clear polyethylene matrices. Five recordings were made with each material at each storage temperature. Results. There is a temperature rise of 3.4–5.5 C when the resins were autocured in a putty matrix. When the polyvinyl matrix was used the temperature rise increased to 4.0–8.2 C (P < 0.001). The temperature rise was reduced to zero when the putty had been precooled in the fridge (P < 0.001) and reduced further following precooling in the freezer (P < 0.001). Significance. The use of a polyvinyl matrix allows higher pulp temperature rises to occur due to the exotherm from provisional resins. Lower temperatures were recorded when putty was used. The temperature rise could be eliminated when the putty was cooled at 4 C prior to reinsertion.File | Dimensione | Formato | |
---|---|---|---|
gastaldi (1).pdf
gestori archivio
Tipologia:
Full Text
Licenza:
DRM non definito
Dimensione
593.81 kB
Formato
Adobe PDF
|
593.81 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.