We developed a new method for the simultaneous quantitative determination of 8-oxo-7,8-hydro- 2′-deoxyguanosine (8-oxodGuo), 8-oxo-7,8-dihydroguanine (8-oxoGua), 8-oxo-7,8-dihydroguanosine (8-oxoGuo), and the corresponding non-oxidized forms, 2′-deoxyguanosine (dGuo), guanine (Gua) and guanosine (Guo), in human urine samples by liquid chromatography–tandem mass spectrometry. Differences in the ionization of analytes in different urine batches with variable matrix effects were effectively compensated for by internal standardization with stable isotope-labelled analytes. The method was sensitive enough to allow the determination of background levels of these biomarkers and was applied to characterize the interand intraindividual variability of biomarkers in the diurnal profile of concentrations in 24 healthy volunteers. When normalized for creatinine, none of the biomarkers was affected by sampling time, thus ruling out any circadian rhythm for nucleic acid oxidation in urine.
Quantitative determination of urinary 8-oxo-7, 8-dihydro-2′-deoxyguanosine, 8-oxo-7,8-dihydroguanine, 8-oxo-7,8-dihydroguanosine, and their non-oxidized forms: daily concentration profile in healthy volunteers
DE PALMA, Giuseppe;
2010-01-01
Abstract
We developed a new method for the simultaneous quantitative determination of 8-oxo-7,8-hydro- 2′-deoxyguanosine (8-oxodGuo), 8-oxo-7,8-dihydroguanine (8-oxoGua), 8-oxo-7,8-dihydroguanosine (8-oxoGuo), and the corresponding non-oxidized forms, 2′-deoxyguanosine (dGuo), guanine (Gua) and guanosine (Guo), in human urine samples by liquid chromatography–tandem mass spectrometry. Differences in the ionization of analytes in different urine batches with variable matrix effects were effectively compensated for by internal standardization with stable isotope-labelled analytes. The method was sensitive enough to allow the determination of background levels of these biomarkers and was applied to characterize the interand intraindividual variability of biomarkers in the diurnal profile of concentrations in 24 healthy volunteers. When normalized for creatinine, none of the biomarkers was affected by sampling time, thus ruling out any circadian rhythm for nucleic acid oxidation in urine.File | Dimensione | Formato | |
---|---|---|---|
Andreoli_Biomarkers2009_online.pdf
gestori archivio
Tipologia:
Full Text
Licenza:
DRM non definito
Dimensione
405.47 kB
Formato
Adobe PDF
|
405.47 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.