BACKGROUND: Interferon-gamma release assays (IGRAs) have high specificity and sensitivity for the diagnosis of tuberculosis (TB) infection. However, their role as a screening tool in children with immunodeficiency disorders is still unclear. In the present study, we performed a contact investigation using serial IGRAs on children with immunodeficiency conditions exposed to a contagious TB patient. METHODS: Children who were exposed to a contagious TB case underwent serial QuantiFERON(®) TB Gold In-Tube (QFT-GIT) and T-SPOT(®).TB (T-SPOT) testing. RESULTS: Eighteen children were tested. At the first testing, only two children (11 %) were positive to T-SPOT. Indeterminate results were more frequent with QFT-GIT (35 %) than with T-SPOT (12 %). In the multivariable analysis, a statistically significant association of lymphocyte count <500 cells/mm(3) (p < 0.00005) and low age (p = 0.03) with indeterminate results for the QFT-GIT test but not for T-SPOT (p = 0.10 and p = 0.88, respectively) was found. At the end of October 2012, 15 of the 18 children were alive and none developed active TB disease. CONCLUSION: T-SPOT provided more determinate results and was less influenced by low age and lymphocytopenia than QFT-GIT in this population of immunodeficient children. These findings suggest that T-SPOT is a more accurate test for the identification of TB infection in young children with lymphocytopenia and should be preferred to QFT-GIT under such specific conditions. PMID: 23575516 [PubMed - indexed for MEDLINE]

Contact investigation based on serial interferon-gamma release assays (IGRA) in children from the hematology-oncology ward after exposure to a patient with pulmonary tuberculosis.

BONFANTI, Carlo;MATTEELLI, Alberto
2013-01-01

Abstract

BACKGROUND: Interferon-gamma release assays (IGRAs) have high specificity and sensitivity for the diagnosis of tuberculosis (TB) infection. However, their role as a screening tool in children with immunodeficiency disorders is still unclear. In the present study, we performed a contact investigation using serial IGRAs on children with immunodeficiency conditions exposed to a contagious TB patient. METHODS: Children who were exposed to a contagious TB case underwent serial QuantiFERON(®) TB Gold In-Tube (QFT-GIT) and T-SPOT(®).TB (T-SPOT) testing. RESULTS: Eighteen children were tested. At the first testing, only two children (11 %) were positive to T-SPOT. Indeterminate results were more frequent with QFT-GIT (35 %) than with T-SPOT (12 %). In the multivariable analysis, a statistically significant association of lymphocyte count <500 cells/mm(3) (p < 0.00005) and low age (p = 0.03) with indeterminate results for the QFT-GIT test but not for T-SPOT (p = 0.10 and p = 0.88, respectively) was found. At the end of October 2012, 15 of the 18 children were alive and none developed active TB disease. CONCLUSION: T-SPOT provided more determinate results and was less influenced by low age and lymphocytopenia than QFT-GIT in this population of immunodeficient children. These findings suggest that T-SPOT is a more accurate test for the identification of TB infection in young children with lymphocytopenia and should be preferred to QFT-GIT under such specific conditions. PMID: 23575516 [PubMed - indexed for MEDLINE]
File in questo prodotto:
File Dimensione Formato  
IGRA Infection.pdf

solo utenti autorizzati

Descrizione: IGRA Infection 2013
Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 202.89 kB
Formato Adobe PDF
202.89 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/273903
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
social impact