A three-dimensional (3-D) imaging system based on Gray-code projection is described; it is thought to be used as an integration to the already developed profilometer based on the projection of multifrequency gratings. The Gray-code method allows us to evaluate the 3-D profile of objects that present even marked discontinuities of the surface, thus increasing the flexibility of the measuring system as to the topology of the objects that can be measured. The basic aspects of Gray-code projection for 3-D imaging and profiling are discussed, with particular emphasis devoted to the study of the resolution of the method and to the analysis of the systematic errors. The results of this study allow us to determine the optimal setting of the parameters of the measurement and to develop a suitable calibration procedure. The procedures for implementing the Gray-code method are presented, and some interesting experimental results are reported. Calibration of the system reveals an accuracy of 0.2 mm, corresponding to 0.1% of the field of view.

Three dimensional Imaging based on Gray Code projection: Characterization of the the measuring algorithm and development of a measuring system for industrial applications

SANSONI, Giovanna;DOCCHIO, Franco
1997-01-01

Abstract

A three-dimensional (3-D) imaging system based on Gray-code projection is described; it is thought to be used as an integration to the already developed profilometer based on the projection of multifrequency gratings. The Gray-code method allows us to evaluate the 3-D profile of objects that present even marked discontinuities of the surface, thus increasing the flexibility of the measuring system as to the topology of the objects that can be measured. The basic aspects of Gray-code projection for 3-D imaging and profiling are discussed, with particular emphasis devoted to the study of the resolution of the method and to the analysis of the systematic errors. The results of this study allow us to determine the optimal setting of the parameters of the measurement and to develop a suitable calibration procedure. The procedures for implementing the Gray-code method are presented, and some interesting experimental results are reported. Calibration of the system reveals an accuracy of 0.2 mm, corresponding to 0.1% of the field of view.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/27151
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 142
  • ???jsp.display-item.citation.isi??? 126
social impact