Purpose: To evaluate the clinical efficacy of user-friendly software for the measurement of intraretinal hyporeflective spaces expression of macular edema. Methods: Fifteen consecutive patients with diabetic retinopathy with clinically significant macular edema were examined using conventional spectral domain optical coherence tomography (OCT). A new composite software application, OCT-measurement analysis tool (OCT-MAT), was developed to automatically process and analyze OCT B-scans by means of image acquisition, filtering, and elaboration, together with hyporeflective area recognition and measurement in µm. The same macular areas were measured manually, and then compared to the measurements obtained by the automated OCT-MAT software. A statistical test analysis was applied (statistical significance level at p<0.05). The repeatability and reproducibility coefficient for the automated software was computed using the Wilcoxon matched pair test (5% significance level). Results: In all patients, the software effectively measured the number and extension of intraretinal hyporeflective spaces in µm. The comparison between mean manual measurements and OCT-MAT measurements (0.478 ± 0.300 × 10 vs 0.471 ± 0.321 × 10 µm) showed correct correspondence . Moreover, the OCT-MAT software showed good repeatability and reproducibility (coefficient below 3%). Conclusions: OCT-MAT allows the precise measurement of macular edema in terms of the number of empty spaces and their size in all patients. Its daily clinical application might give precise information regarding the evolution of macular edema and the efficacy of therapy.

Clinical analysis of macular edema with new software for SD-OCT imaging

SANSONI, Giovanna;SEMERARO, Francesco;
2013-01-01

Abstract

Purpose: To evaluate the clinical efficacy of user-friendly software for the measurement of intraretinal hyporeflective spaces expression of macular edema. Methods: Fifteen consecutive patients with diabetic retinopathy with clinically significant macular edema were examined using conventional spectral domain optical coherence tomography (OCT). A new composite software application, OCT-measurement analysis tool (OCT-MAT), was developed to automatically process and analyze OCT B-scans by means of image acquisition, filtering, and elaboration, together with hyporeflective area recognition and measurement in µm. The same macular areas were measured manually, and then compared to the measurements obtained by the automated OCT-MAT software. A statistical test analysis was applied (statistical significance level at p<0.05). The repeatability and reproducibility coefficient for the automated software was computed using the Wilcoxon matched pair test (5% significance level). Results: In all patients, the software effectively measured the number and extension of intraretinal hyporeflective spaces in µm. The comparison between mean manual measurements and OCT-MAT measurements (0.478 ± 0.300 × 10 vs 0.471 ± 0.321 × 10 µm) showed correct correspondence . Moreover, the OCT-MAT software showed good repeatability and reproducibility (coefficient below 3%). Conclusions: OCT-MAT allows the precise measurement of macular edema in terms of the number of empty spaces and their size in all patients. Its daily clinical application might give precise information regarding the evolution of macular edema and the efficacy of therapy.
File in questo prodotto:
File Dimensione Formato  
Azzolini_2013 def EJO.pdf

gestori archivio

Tipologia: Full Text
Licenza: DRM non definito
Dimensione 2.65 MB
Formato Adobe PDF
2.65 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/264107
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact